Using a Master Clock
The performance can be improved further by adding a Vivaldi Master Clock to the system.
Figure 3 – Using the Vivaldi Transport, DAC and Clock together
•
Use the DAC
’
s
Input
button to select the input you want to use (
AES1+2
in the example).
•
Connect one of the Clock
’
s
Group 1 Word Clock Outputs
to the
Transport’s
Word Clock In
put
and the
DAC’
s
Word Clock In
put
1
.
•
Use the Clock
’
s
Freq1
button to set the Group 1 outputs to
44.1kHz
.
The Transport will lock to the Word Clock and display this icon.
Set the DAC
’
s
Settings > Sync Mode
menu page to
Word Clock In1
and allow the
system to re-lock.
Proceed to Step 3.
Analogue
outputs
to Amplifier