D E T A I L E D A R C H I T E C T U R E
Data Device Corporation
SB-3624XIX-3L0 Manual
www.ddc-web.com
Rev D -10/15
50
6.5.2 Set Oscillator Frequency
1. Enter (8) to change frequency.
2. To change the Oscillator frequency, enter the bit multiplier. The bit
multiplier, which is an integer, is determined by the following formula:
Frequency = (bit multiplier) X (Hz/bit)
Table 12. Oscillator Frequency
Board
Type
Output Scaling
(Hz/bit)
Examples
Bit
Multiplier
Resultant
Frequency
Bit Multiplier
Range
60 Hz
7.6 Hz/bit
60.8 Hz = (8) X (7.6)
8
60.8 Hz
8 - 255
402.8 Hz = (53) X (7.6)
53
402.8 Hz
400 Hz
57.8 Hz/bit
404.6 Hz = (7) X (57.8)
7
404.6 Hz
6 - 255
2023.0 Hz = (35) X (57.8)
35
2023.0 Hz
6.5.3 Set Amplitude
1. Enter (9) to change Amplitude
2. To change the Oscillator amplitude, enter the bit multiplier. The bit
multiplier, which is an integer, is determined by the following formula:
Amplitude = (bit multiplier) X (mV/bit)
Table 13. Oscillator Amplitude
Model
Number
Output Scaling
(mV/bit)
Examples
Bit
Multiplier
Resultant
Amplitude
Bit
Multiplier
Range
IA
135.0 mVrms/bit
26.0550 Vrms = (193) X (.135)
193
26.0550 Vrms
0 - 255
IB
635.0 mVrms/bit
115.5700 Vrms = (182) X (.635)
182
115.5700 Vrms
0 - 210
5.6 LabVIEW Support Software Installation
The SB-36240S0 Windows Software package is required to be installed prior to
installation. Refer to the ‘Install.txt’ file contained in the LabVIEW Support package for
complete installation instructions.