De Gier B.V., Westlandseweg 9, 2291 PG WATERINGEN, THE NETHERLANDS,
+31 (0)174 292089, sales@degierdrivesystems.com, www.degierdrivesystems.com
Versie 1 – 2020 / 03 / 01
17
Connecting and commissioning may only be performed by qualified staff..
Mortal danger! Mortal danger due to electrical or mechanical forces!
Before starting to work on the motor gearbox and associated parts, always disconnect the power supply by
means of the main or isolation switch and secure it against re-activation by using a padlock.
5.1 Mains connection for AC-motors with 1 phase
Caution
Mains voltage may differ 5% at most from the voltage mentioned on the electric motor’s type plate.
The electrical diagram can be found in the appendix on page 24.
1. Remove the protective cover of the terminal strip of the electric motor.
2. Insert the cable through the cable gland and rubber gasket.
3. Connect the green/yellow lead to the PE terminal (earth).
4. Connect the neutral lead (N) to terminal U1 and connect the live lead (L) to terminal V1 or W1 as shown in the
electrical diagram, depending on the desired direction of rotation.
5. Move the motor gearbox in a position between both limit switches by use of a hexagonal tool.
6. Check the rotation direction of the output shaft, relative to the limit switch and the control box. Swap the live lead
between V1 and W1 if necessary (see image).
7. Fit the protective cover and gasket of the terminal strip back onto the electric motor and tighten the cable gland.
8. Ensure that the cables are clear of any moving parts.
5.2 Mains connection for AC-motors with 3 phases
Caution
Mains voltage may differ 10% at most from the voltage mentioned on the electric motor’s type plate.
Please note!
Swapping the supply voltage phase connections changes the direction of rotation of the drive. Switching pha-
ses will affect the functioning of the limit switch system.
The wiring diagram can be found in the appendix on page 23.
1. Remove the protective cover of the terminal strip of the electric motor;
2. Insert the cable through the cable gland and rubber
gasket.
3. Connect the green/yellow lead to the PE terminal (earth).
4. Connect phase L1 to terminal U1, phase L2 to terminal V1
and phase L3 to terminal W1 (see image).
5. Move the motor gearbox to a position between both limit
switches by use of a hexagonal tool.
6. Check the rotation direction of the output shaft relative to
the limit switch and the control box. Swap two phases, if
necessary.
7. Fit the protective cover and gasket of the terminal strip
back onto the electric motor and tighten the cable gland.
8. Ensure that the cables are clear of any moving parts.
5. Electrical connection
W2
U2
V2
U1
V1
W1
(PE/GND)
Aansluitklemmen elektromotor (3 fase)