background image

Safety reference: All codes are to be           

securely stored. Do 

NOT use personal data 

(i.e. Birthdays, telephonenumbers, etc) as a 

code. Change the factory code before you 

start using the safe!!!

 

 

Manual DRS Combi Fire private safes

 

 

EM 2020

 

Setting the time delay and opening window time

 

Continuation: open with time delay

 

You can only change or delete the delay setting during the open 
window time.

 

Enter a valid code. After the delay period the opening window 

will start. The light flashes 1x a second and 

beeps.

 

• 

Press and hold 

“9” 

until a double signal sounds. The 

light will illuminate when performing the following 

actions. 

 

 
 

• 

Enter your manager code (see the previous step) You

ll 

hear a double signal                       

   

 

  

(Pay attention! The code underneath is an example)

 

• 

You can delete the delay and opening window

 

by 

entering

 00 for the delay setting and 01 for the 

opening window time

 

 

• 

Enter the delay setting and opening window again to 

delete the setting. 

 

Time delay: 

The time between the first and second code 

entry in minutes.  

 

Open window time: 

The period of time in minutes during 

which the code can be entered a second time and the lock 

can be opened.  

 

Changing or deleting the time delay values can only 

be done in open window time.  

 

Press and hold 

‘9’ 

until a double signal sounds. The LED 

will illuminate when performing the following actions: 

 

 
 

• 

Enter your manager code                                 

You

ll hear a double signal  

 

• 

Enter the delay setting and opening window time. 

Time delay 

min. 01 

-

 max. 99 minutes.              

Open window time

  min. 01 

-

 max. 99 minutes.        

In this example: 2602 for 

a delay of 26 minutes 

and 

a opening window time of 2 minutes

.

(Pay attention! The code underneath is an example)

 

 

 

 

• 

Enter the delay setting and opening window time 

again.

 

 

(Pay attention! The code underneath is an example) 

 

 

 

 

Open with time delay

 

Deleting the delay setting

 

Enter the code (i.e. 1

-

1

-

1

-

1

-

1

-

1), after entering a right 

code, a double signal sounds an time delay starts. Durin 

time delay expires the light flashes every 10 seconds. After 

time delay has elapsed a double signal sounds and the 

open window starts, 

 

 
 

During the open window the light flashes and the lock 

beeps every second. To open the lock a valid code has to 

be entered again during the open window. After entering a 

right code a double signal sounds. You can unlock the door. 

If the lock is not open within 3 seconds the lock will auto-

matically lock again. If the open window expires without 

entering a valid code the lock is secured again with time 

delay.

 

If the lock is set to dual combo one valid code starts time 

delay. During the open window two valid codes have to be 

entered to open the lock.

 

Press a random key to break off time delay. 

 