background image

 

3.

 

SAFETY INSTRUCTIONS  

 

!

 

-  Professional  use:  this  luminaire  has  been  designed  for  professional  use  and  must  be 

operated by qualified personnel only. Not for residential use.  

!

 

- Grounding: WARNING: This luminaire must be grounded 

!

 

-  Electrical  connections:  IMPORTANT:  the  cores  in  this  mains  lead  are  colored  in 

accordance with the following code: 

 

 
In case the colors of the cores do not correspond to the colors of the connection points on your plug, please 
proceed as follows: 
- the green or green and yellow core must be connected to the connection point marked with the letter E or with 
the symbol 

or colored on green or in green-yellow 

- the blue (or white) core must be connected to the connection point marked with the letter N or colored in black 
- the brown (or black) core must be connected to the connection point marked with the letter L or colored in red 
 
 
Working conditions 
 

!

 

Working Position 

 

Lighting fixture: Max. Tilting 

±

90° from horizontal 

Lamp: S90 

!

 

Ambient Temperature, t

a

 

+45° C Max. 

!

 

Minimum distances from 
inflammable surfaces 

Top 

Back 

Sides 

Front 

0,3 m. 

0,1 m. 

0,1 m. 

1 m. 

 

The  luminaire  should  never  be  OPERATED  close  to  inflammable  materials.  The  ones  indicated  in  the  above 
table are the minimum distances recommended. Other requirements for safe use are:  
A.

 

Do not cover the apertures of the luminaire housing. They are essential for correct ventilation.  

B.

 

Use only original accessories and spares from De Sisti Lighting. 

C.

 

Before hanging the luminaire ensure that the suspension point (or the stand) is properly rated to accept the 
luminaire weight. 

D.

 

In case of pole operated use, fit only a P.O. stirrup from De Sisti Lighting. 

E.

 

A suitable secondary safety suspension device (safety cable, chain or equivalent) must be fitted between the 
suspension point and the eyelet at the front of the body . 

 

WARNING : DO NOT  MOUNT THE LUMINAIRE ON A NORMALLY FLAMMABLE SURFACE . 

 
4.

 

INSTALLATION INSTRUCTIONS 

 
Before connecting the luminaire to the electrical mains ensure that: 

A.

 

Earth line is present on the power socket. 

B.

 

The mains voltage is within the rated range of the luminaire (see technical data on the rating label) 

C.

 

The lamp fitted: 

-

 

is among the usable lamps (see point 6 or check with your De Sisti dealer) 

-

 

has the same nominal voltageas the mains supply 

-

 

has a nominal voltage not higher than maximum power of the luminaire 

EUROPE 

AMERICA 

Ground 

Green & yellow 

Green or green & yellow 

Neutral 

Blue 

White 

Live 

Brown 

Black 

Summary of Contents for LEONARDO

Page 1: ...LEONARDO 1000 W Quartz Halogen Fresnel SPORTLIGHT INSTRUCTION MANUAL ...

Page 2: ...for the professional entertainment industry menas you can depend upon the quality of this product The Leonardo 1 kW is a compact highly efficient Fresnel lens spotlight using tungsten quartz halogen filament lamps having GY 22 socket L C L of 63 5 mm and max 1 kW power NOTE Also available on special request a version using tungsten quartz halogen filament lamps having GX 9 5 socket L C L of 55 mm ...

Page 3: ...D close to inflammable materials The ones indicated in the above table are the minimum distances recommended Other requirements for safe use are A Do not cover the apertures of the luminaire housing They are essential for correct ventilation B Use only original accessories and spares from De Sisti Lighting C Before hanging the luminaire ensure that the suspension point or the stand is properly rat...

Page 4: ...e adopted A Ensure the luminaire is electrically isolated from the power supply B Wait least 5 minutes from switching off to avoid risk of injury from possible lamp explosion Then open lens door WARNING after the above mentioned time the lamp may still be very hot use proper thermal protection Eg Gloves C Check that the new lamp is of the correct type see item 5 C D Replace the lamp taking good no...

Page 5: ...Weight of fixture M O 6 3 kg P O 7 6 Kg Weight of barndoor 4 leaf 0 63 kg 8 leaf 0 85 kg Size of barndoor ring Seat diameter 192 mm Ring diameter 190 mm 7 Weight of color frame 0 13 Kg Size of scrims color frame Seat diameter 187 mm Accessory diameter 185 mm 7 Lens diameter 150 mm USABLE LAMPS base watt filament 230 V 120 V ANSI LIF ANSI LIF G22 500 W MP No Available EGN G22 650 W MP FKH CP 39 Not...

Page 6: ... lamp condition must be checked every 100 working hours For lamp replacement follow the procedure of point 5 and the instruction of the lamp manufacturer C Check the condition of the safety shield see chapter 5 D Installation Instructions before every use 8 SAFETY STANDARDS Europe The product conforms the Applicable European Directives Standards America the product conforms NEC UL stds Low voltage...

Reviews: