7.
PERIODIC INSPECTION
A.
The condition of the internal wiring insulation and of the input cable shall be inspected and tested every
500 working hours and at least once a year. This frequency may need to be increased if rough or
unknown (eg. Rental) treatment is incurred. Replace only with original De Sisti spare parts. Non-original
cables may not withstand the thermal and mechanical conditions of use
B.
The lamp condition must be checked every 100 working hours. For lamp replacement follow the
procedure of point 5 and the instruction of the lamp manufacturer.
C.
Check the condition of the safety shield (see chapter 5-D – Installation Instructions) before every use.
8.
SAFETY STANDARDS
Europe: The product conforms the Applicable European Directives &
Standards
America:
the
product
conforms NEC & UL stds.
-
Low voltage directive: 73/23/EEC (as amended by 93/68/EEC)
-
EMC Directive: 89/336/EEC (as amended by 92/31/EEC & by
93/68/EEC)
-
European Standards: EN 60598-2-17, EN 60598-1, EN 61547
UL Standard: 1573
Approved by UL: file E116219