3
Instructions
Flame effect / Light bulb replacement
Caution! Bulbs will become very hot; allow at least 10 minutes for bulbs to be cool before touching
The flame effect on this electric stove heater is created by two 4 watt LED bulbs with an E14 (small) socket
base. Only use this type of light bulb. To service light bulbs, unplug power cord from outlet, locate access
panel on back of stove. Remove screws and panel. Light bulbs may come loose or may be damaged during
shipping. If flame effect does not work properly, check to be certain that both bulbs are finger tight and are in
working order. Replace light bulbs as needed. Replace access panel. Do not operate with out access panel
in place. Do not remove back cover of heater, as there are no serviceable parts.
Controls / Operation
On the top right of the unit you will see the control panel, which includes 3 switches and 2 adjustors; namely,
one on/off switch, two heater switch, one dimming adjustor and one thermostat adjustor.
PLUG REPLACEMENT
If the plug is damaged and requires replacement, follow the wiring instructions supplied with the new plug.
• The green and yellow wire must be connected to the terminal marked with the letter E or the earth symbol.
• The blue wire must be connected to the terminal marked with the letter N.
• The brown wire must be connected to the terminal marked with the letter L.
• A 13 amp plug to BS 1363 must be fitted a 13 Amp fuse to BS 1362.
* For your safety and protection, this unit is earthed through the power cord plug when plugged into a
matching wall socket. If you are not sure whether the wall sockets in your home are properly earthed, consult
a qualified electrician. Do not use plug adaptors or extension cords with this unit.
Flame ON/OFF Switch:
Turn on this switch and the flame effect will work. Turn off the switch and the flame and heat will not work.
(Before plugging into the power outlet, turn off the flame switch).
900/1800W ON/OFF Switch:
Turn on the first switch for 900 watts heat and the second switch for 1800 watts of heat. Note the second
switch will only work once the first switch has been turned on.
Dimming Adjustor:
Rotate this control to adjust the intensity of the flame. The flame intensity control can only be used when the
switch is on.