2 2 4 R R
Operating instructions and warnings
17
Basic installation Complete installation
By pressing the “ OK “ key when the control board awaits further instructions (“- - - -”) the display shows
some vertical segments: each one of them is associated to one of the control board inputs (see the picture
above). When the segment is lighted it means that the contact associated to it is closed, on the contrary,
when it is switched off the contact is open. In order to do this:
8.2
Setup and memorization of motor stroke
WARNING During motors stroke memorisation, the control board detects automatically the presence
and type of photocells, safety devices and limit switches which are installed. It is therefore essential that
during this phase the latter be properly connected and working.
In case only one motor works, P29=1
must be programmed immediately.
A7
Instructions
Function
Display
The control board is ready to receive instructions
Leaf 1 positioning
Scroll down the parameters until you visualize procedure P001
Confirm! The control board is ready for the positioning of leaf 1
Position leaf 1 in its standstill position while opening
1
Confirm! The control board has memorized the leaf position
Leaf 2 positioning
Scroll down the parameters until you visualize procedure P002
Confirm! The control board is ready for the positioning of leaf 2
Position leaf 2 in its standstill position while opening
1
Confirm! The control board has memorized the leaf position
Motors stroke memorization
Scroll down the parameters until you visualize procedure P003
Confirm! The control board awaits a further confirmation
Confirm by pressing on the OK key for a few seconds! The procedure starts
Now motor 2 starts to close in the slow down phase until it reaches the stroke
end while closing (or the limit switch, if used), shortly after that, motor 1 also
starts to close in the slow down phase until it reaches the stroke end while closing
(or the limit switch, if used).
On the display you will read “----”. Motor stroke memorization done!
1
By pressing on the key the leaf must open, by pressing on the key the leaf must close. If this does not happen, you
must swap the two motor cables. Only if you use limit switches, first position the leaf where you want it to stop in closing and
then adjust the closing cam so that it presses on the limit switch associated to it in that point. Then position the leaf in the
opening position and adjust the opening cam so that it presses on the limit switches associated to it in that point.
FC
C
2
SI
C
1
FC
A
1
FO
TO
C
FC
A
2
FC
C
1
SI
C
2
P
ED
O
N
ST
A
R
T
ST
O
P
FC
C
2
SI
C
1
FC
A
1
FO
TO
C
FC
A
2
FC
C
1
SI
C
2
P
ED
O
N
ST
A
R
T
ST
O
P
Summary of Contents for 224RR
Page 1: ......