2 2 4 R R
Operating instructions and warnings
21
9 MAINTENANCE
WARNING Any installation, maintenance or repair operation on the whole system must be carried
out exclusively by qualified personnel. All these operations must be performed only after disconnecting
the power supply, and operating in strict compliance with the electrical standards and regulations in
force in the nation of installation.
A5
WARNING: With control boards range “RR” disconnect the power supply wires before
unlocking the operator manually. When you start the operator again the first operation
will bring the door to a complete closing. If you do not follow this procedure the door will
lose its right positioning.
10 PRODUCT DISPOSAL
In line with EU Directive 2002/96/EC for waste electrical and electronic equipment (WEEE), this
electrical product must not be disposed of as unsorted municipal waste. Please dispose of this product
by returning it to your local municipal collection point for recycling.
11 COMPLETE CLOSING ASSEMBLY
Remember that everyone who sells and/ or motorises doors/gates becomes the manufacturer of the
automated door/gate machine, and must therefore prepare and preserve a technical folder containing
the following documents (see Machinery Directives Enclosure V).
• Assembly drawing of the automatic door/gate.
• Electrical connection and control circuit diagram.
• Risk analysis including: a list of the essential safety requirements provided in machine Directive
Enclosure I; a list of the risks posed by the door/gate and a description of the implemented solutions
The installer must also:
• Keep these operating instructions and the instructions for all other components in a safe place.
• Prepare the operating instructions and general safety warnings (by filling up these operating instruc-
tions) and hand a copy to the end user.
• Fill in the maintenance handbook and hand a copy to the end user
• Draw up the EC declaration of conformity and hand a copy to the end user.
• Fill in the complete EC label or plate and apply it to the automated door/gate.
N.B. The technical folder must be kept for inspection by the competent national authorities for at
least ten years starting from the date of the automatic door/gate manufacturing.
WARNING DEA System reminds all users that the selection, positioning and installation of all ma-
terials and devices which make up the complete automation system, must comply with the European
Directives 2006/42/CE (Machinery Directive), 2004/108/CE (electromagnetic compatibility), 2006/95/
CE (low voltage electrical equipment). In order to ensure a suitable level of safety, besides complying
with local regulations, it is advisable to comply also with the above mentioned Directives in all extra
European countries.
WARNING Wrong assessment of impact forces may cause serious damage to people, animal and
things. DEA System reminds all personnel that the installer must ascertain that these impact forces,
measured according to EN 12445 prescriptions, are actually below the limits indicated by EN12453
regulation.
WARNING Any external safety device installed in order to conform to the limits set for impact forces
must comply with EN12978.
Summary of Contents for 224RR