40
24V
230V
OPERATING PARAMETERS
Saf
eties
self-t
est:
if
=
0
24V
output
with
aut
ot
est
disabled;
if
=
1
24V
outp
ut
for
saf
eties
with
self-t
est
(it
turn the output of
f and check the contact opening bef
ore each maneuv
er).
Att
ention:
In
or
der
to
w
or
k
in
self-t
est
mode,
all
de
vices
must
be
connect
ed
to
the
stabilized
output
24V_S
T
(33-34 f
or 230V) (1-2 f
or 2
4V), and be wired and aligned bef
ore the mo
tor str
ok
e learning (P003).
• 000: “ne
t po
w
er supply (saf
eties self-t
est disabled)
• 00
1: “saf
eties self-t
est enabled
Activ
ation
of
SAS
function
(with
NET_EXP
only)
: SAS
output
is
connect
ed
to
an
in
put
ST
OP
/
SAS
INPUT
of
a
second
co
ntr
ol
panel,
causing
the
operation
“trap
man”
(disabling
the
opening
of
the
second
door
as
long
as the fir
st is no
t com
ple
tely closed).
If
this
para
me
ter
is
enabled
af
ter
a
res
et,
it
per
forms
an
aut
omatic
RESP
during
which
the
SAS
output
is
no
t
activ
at
ed. If limit switches are present and the
y are crushed af
ter a rese
t, the RESP is no
t e
xecut
ed.
W
arning:
if
bo
th
door
s
are
manually
unlock
ed
and
mo
ved
from
the
closed
position
creat
es
the
int
erlock
condition. Y
ou will then need t
o manually close at least one of the tw
o door
s.
• 000: “SAS function” deactiv
at
ed
• 00
1: “SAS function” activ
at
ed
Unused parame
ter
Unused parame
ter
Unused parame
ter
Unused parame
ter
Configuration paramet
er
s dedicat
ed t
o the e
xpansion card NET_EXP (f
or a det
ailed descrip
tion of the paramet
er
s, ref
er t
o the ins
truction manual).