RESPONSIBILITIES OF THE INSTALLER
Remember that anyone who sells and/or motorises doors/gates becomes the manufacturer of the automatic door/gate
machine and must therefore prepare and conserve a
technical folder
that contains the following documents (see Machinery
Directive Enclosure V):
• Assembly drawing of the automatic door/gate;
• Electrical connection and control circuit wiring diagram;
• Risk analysis including: a list of the essential safety requirements provided in Machinery Directive Enclosure I; a list of the risks
posed by the door/gate and the description of the solutions adopted.
• Keep these operating instructions in a safe place together with the instructions for all the other components;
• Prepare these operating instructions and general safety warnings (for the completion of these operating instructions) and
deliver a copy to the final user;
• Fill out the maintenance register and deliver a copy to the final user;
• Draft the CE declaration of conformity and deliver a copy to the final user;
• Fill out the complete CE label or plate and apply it to the door/gate.
Note: The technical folder must be conserved for inspection by the competent national authorities for at least ten years from
the date construction of the automatic door/gate.
“OPERATING CONTROL” table
Type of use
Type of control
Informed users
(private areas)
Informed users
(public areas)
Uninformed users
Person-present control
Pushbutton control
Pushbutton control with key
The person-present control is
not possible
Pulse control with the gate in
sight
Force limitation
or
presence detectors
Force limitation
or
presence detectors
Force limitation
and photocells
or presence detectors
Pulse control with the gate not
in sight
Force limitation
or
presence detectors
Force limitation
and photocells
or presence detectors
Force limitation
and photocells
or presence detectors
Automatic control
(i.e. control with
timed closing)
Force limitation
and photocells
or presence detectors
Force limitation
and photocells
or presence detectors
Force limitation
and photocells
or presence detectors
Pos.
Description
1
102 Lux key selector
2
Remote-control
3
Pilly 60 column
4
Safety edge
5
Electric lock
6
FLIC/rad digital
selector
7
104 Lux series
photocells
8
LOOK
9
Lumy flashing light
10
Control box
“EXAMPLE OF TYPICAL INSTALLATION” picture
WARNING
In case a little pedestrian door is installed on the gate and it may be opened while the gate moves, it is necessary
to adopt a limit switch to grant that door closing while the gate moves and to maintain this protective function also in case of failure
of this security limit switch.