STOP N
EN-2
WARNING
Check that there is a switch or an omni polar magneto-thermal circuit bre-
aker that enables complete disconnection in case of over voltage category III conditions
installed upstream from the power system.
WARNING
To ensure an appropriate level of electrical safety always keep the 230V
power supply cables apart (minimum 4mm in the open or 1 mm through insulation) from
low voltage cables (motors power supply, controls, electric locks, aerial and auxiliary
circuits power supply), and fasten the latter with appropriate clamps near the terminal
boards.
WARNING
If the power cable is damaged, it must be replaced by the manufacturer or
its technical assistance service or, in any case, by a person with similar quali
fi
cations to
prevent any risk.
WARNING
All installation, maintenance, cleaning or repair operations on any part of
the system must be performed exclusively by quali
fi
ed personnel with the power supply
disconnected working in strict compliance with the electrical standards and regulations
in force in the nation of installation.
Cleaning and maintenance destined to be performed by the user must not be performed
by unsupervised children.
WARNING
Using spare parts not indicated by
DEA
System and/or incorrect re-assem-
bly can create risk to people, animals and property and also damage the product. For this
reason, always use only the parts indicated by
DEA
System and scrupulously follow all
assembly instructions.
WARNING
Changing the closing intensity could lead to dangerous situations. Therefore,
quali
fi
ed personnel should only perform increases to the closing force. After adjustment,
compliance with regulatory limits values should be detected with a force impact-mea-
suring instrument. The sensitivity of the obstacle detection may be adjusted gradually
to the door (see programming instructions). The anti-crushing device operation must be
checked after each manual adjustment. Manual modi
fi
cation of the force can only be
done by quali
fi
ed personnel by performing the measurement test according to EN 12445.
Modi
fi
cations to the force adjustment must be documented in the machine manual.
WARNING
The compliance of the internal sensing obstacles device to requirements
of EN12453 is guaranteed only if used in conjunction with motors
fi
tted with encoders.
WARNING
Any external security devices used for compliance with the limits of impact
forces must be conform to standard EN12978.
WARNING
In compliance with EU Directive 2012/19/EU on waste electrical and elec-
tronic equipment (WEEE), this electrical product should not be treated as municipal
mixed waste. Please dispose of the product and bring it to the collection for an appropri-
ate local municipal recycling.
E
VERYTHING
THAT
IS
NOT
EXPRESSLY
PROVIDED
FOR
IN
THE
INSTALLATION
MANUAL
IS
NOT
ALLOWED
. C
ORRECT
OP
-
ERATOR
OPERATION
IS
ONLY
ENSUED
WHEN
THE
REPORTED
DATA
IS
RESPECTED
. T
HE
COMPANY
DOES
NOT
RESPOND
FOR
DAMAGE
CAUSED
BY
FAILURE
TO
COMPLY
WITH
THE
INSTRUCTIONS
CONTAINED
IN
THIS
MANUAL
. W
ITHOUT
AF
-
FECTING
THE
ESSENTIAL
FEATURES
OF
THE
PRODUCT
,
THE
C
OMPANY
RESERVES
THE
RIGHT
TO
MAKE
ANY
CHANGES
DEEMED
APPROPRIATE
AND
AT
ANY
TIME
IN
ORDER
TO
TECHNICALLY
,
STRUCTURALLY
AND
COMMERCIALLY
IMPROVE
THE
PRODUCT
WITHOUT
BEING
REQUIRED
TO
UPDATE
THIS
DOCUMENT
.
Summary of Contents for STOP24NET/N/L-F
Page 2: ......
Page 75: ...STOP N I 3 3 4 5 6 ...
Page 76: ...STOP N I 4 7 8 9 10 Clack 11 12 ...
Page 95: ......