background image

12

6.5

BLOCKAGE BETWEEN FILTER PAN AND FLEX HOSE VALVE?

Disconnect oil line from

filter pan to pump at the

pump end.

Pump is clear; plug is

in the bottom of the

filter pan or in the line

from the pan to pump.

Disconnect line at filter pan.

Can you blow air through line

from pump to pan?

Turn pump ON and allow it to

operate for a few seconds to ensure

it does not run backwards.

Put your finger over the

pump inlet.  Is suction

present?

Remedy problem and continue

filtration process.

Blockage is in pump or in

the discharge line.

Blockage is

suspected between

filter pan bottom and

flex hose disconnect.

Yes

No

Yes

Line is blocked. Remove

line, soften and clear

solidified shortening.

No

Reconnect line and

operate pump.  If still

no oil flow, blockage

is in bottom of pan.

Summary of Contents for Portable Filters MF90 Series

Page 1: ...quipment Service Association recommends using CFESA Certified Technicians Price 6 00 24 Hour Service Hotline 1 800 551 8633 819 5711 05 99 MF90 Series Portable Filters CE Operation Service Parts Manua...

Page 2: ...IRECTLY INTO A PROPERLY GROUNDED THREE HOLE RECEPTACLE DO NOT CUT OFF REMOVE OR OTHERWISE BYPASS THE GROUNDING PRONG ON THIS PLUG IF IT IS NECESSARY TO USE AN EXTENSION CORD IT MUST BE A THREE CONDUCT...

Page 3: ...t your Maintenance Repair Center or call the factory The factory address and phone number are on the cover of this manual To speed up your order the following information is required Model Number Type...

Page 4: ...ctivate the circuit after the failure has been detected and fixed 2 4 RATING PLATE Information on this plate includes the model and serial numbers as well as electrical requirements This data is essen...

Page 5: ...er covers the whole filter pan bottom d Position the hold down ring on top of the filter papers and latch the hold down ring and filter papers securely against the filter pan bottom forming a tight se...

Page 6: ...ed to expedite filtering and prevent burns from splashing oil 4 3 FILTER PREPARATION a Pull the filter unit close to the fryer Remove the filter pan cover b Make certain filter power switches are in O...

Page 7: ...paper on top of the new sheet i Replace the hold down ring and secure j Replace cover k Go to Section 4 5 Operation and continue 4 5 OPERATION Figure 4 1 shows a portable filter installed and ready f...

Page 8: ...nds after air bubbles appear in the fryer vessel before shutting off the filter This will help clear residual shortening oil from the return lines NOTE After filtering it may be necessary to scrape of...

Page 9: ...dditional 10 15 seconds after air bubbles start coming from the oil return line Then drain the flexible hose b Discard the top filter paper sheet after use c Remove the filter pan cover and hold down...

Page 10: ...the filter is less likely to be plugged b If your filter is equipped with a pan heater use it every time before you filter c When pumping hot oil back into the fryer tilt the filter machine to the re...

Page 11: ...is cool before handling Try blowing air through the hose Can you blow air through it Blockage is between bottom of the filter pan and the flexible hose quick disconnect Go to Section 6 5 Submerge hose...

Page 12: ...sheet and use old bottom sheet as new top sheet Reinstall hold down ring If paper is incorrectly installed under hold down ring air may be getting into the system Add correct amount of filter powder...

Page 13: ...pan Turn pump ON and allow it to operate for a few seconds to ensure it does not run backwards Put your finger over the pump inlet Is suction present Remedy problem and continue filtration process Blo...

Page 14: ...g pages correspond to items numbered in the above drawing Not every part is listed or shown on the drawing Some portable filter configurations may not use all of the parts shown in the drawing or may...

Page 15: ...x 46 5cm 16 3 8 x 18 3 8 7 55120 Grid Channel Assembly 1053 Filter Powder 22 7kg 50 lb bag 8 55189 Filter Pan 9 1003 Caster Filter Pan 5cm 2 10 2175 Circuit Breaker 5 Amp 11 1026 Timer Switch 12 1026...

Page 16: ...r 22 7kg 50 lb bag 8 55189 Filter Pan 9 1003 Caster Filter Pan 5cm 2 10 2175 Circuit Breaker 5 Amp 11 1026 Timer Switch 12 1026 1 Knob Timer Switch 13 1083 Switch ON OFF 14 55 0029 Switch Housing 15 5...

Page 17: ...16 8 Wiring Diagrams for the MF90 U 110 and MF90 AU 110 Portable Filter Systems Receptacle P N 2563 230 VAC MF90 U 110 Portable Filter 230V 50Hz CE...

Page 18: ...17 Receptacle P N 2563 MF90 AU 110 Portable Filter 230V 50Hz CE...

Page 19: ...ies 14501 South Broadway Gardenia California 90248 TEL 1 310 323 5000 FAX Parts 1 310 327 3343 FAX Tech Support 1 318 219 7135 Price 6 00 PRINTED IN THE UNITED STATES SERVICE HOTLINE 1 800 551 8633 81...

Reviews: