Page 1: ...rcial Food Equipment Service Association recommends using CFESA Certified Technicians 24 Hour Service Hotline 1 800 551 8633 8196109 FEB 2007 Super Runner Electric Series SR114E Super Runner Series Electric Fryers Service Parts Manual ...

Page 2: ... serial number plate located on the inside of the fryer door DANGER All wiring connections for this appliance must be made in accordance with the wiring diagrams furnished with the equipment Wiring diagrams are located on the inside of the fryer door DANGER Do not store or use gasoline or other flammable vapors and liquids in the vicinity of this or any other appliance WARNING Do not attach access...

Page 3: ... a Temperature Control Board 1 2 1 5 Replacing a Transformer Contactor or Relay 1 2 1 6 Replacing a Power Switch or Indicator Lamp 1 3 1 7 Replacing a Temperature Probe or High Limit Thermostat 1 3 1 8 Replacing a Heating Element 1 4 1 9 Replacing a Frypot 1 4 1 10 Probe Resistance Chart 1 5 1 11 Troubleshooting Guides 1 5 1 12 Wiring Diagrams 1 7 CHAPTER 2 PARTS LIST 2 1 2 1 Accessories 2 1 2 2 C...

Page 4: ... 14 kW 208 3 3 6 4 11 39 14 kW 240 Single 3 4 5 19 59 14 kW 240 3 3 8 3 26 34 14kW 230 400 3 4 6 4 11 21 Interior View of the Control Box Terminal Block Fuse Block Contactors High Limit Reset Switch High Limit Relay Transformer Controller Assembly Single Phase Control Box Shown Note The three phase control box differs from the single phase by eliminating the fuse block and terminal block ...

Page 5: ...y an authorized service agent only 1 2 Temperature Control Knob Calibration If the temperature controller knob requires adjustment do the following 1 Set the temperature controller dial to the desired oil temperature and wait for the temperature to stabilize 2 When the oil temperature reaches operating temperature let the heating elements cycle at least four times indicated by the HEAT light going...

Page 6: ... board and slide the board from the studs Ensure that standoffs remain in place on studs prior to installing new board Install the new board by reversing the previous procedures 6 Perform Procedure 1 2 to recalibrate the temperature control knob 1 5 Replacing a Transformer Contactor or Relay 1 Unplug the power cord Perform Procedure 1 3 Steps 1 2 Accessing the Control Box Electronics 2 Remove all ...

Page 7: ...aining the probe wiring 6 Using an open end wrench loosen the temperature probe or high limit probe Pull the probe through the hole and remove the probe 7 If replacing the high limit thermostat remove the two screws that attach the high limit reset switch to the control box Remove the two wires attached to the high limit reset switch Pull the probe through the bushing in the rear of the control bo...

Page 8: ...dure 1 3 Accessing the Control Box Electronics Steps 1 2 2 Perform Procedure 1 7 Replacing a Temperature Probe Steps 1 7 3 Perform Procedure 1 8 Replacing a Heating Element Steps 1 4 4 Remove the screws holding the fluecap to the side panels 5 Remove the screws attaching the faceplate bracket and heatshield to the front of the frypot 6 Remove the screws securing the frypot to the front frame of th...

Page 9: ...1463 124 325 1604 163 395 1744 202 120 1185 49 190 1330 88 260 1473 127 330 1614 166 400 1754 204 125 1195 52 195 1340 91 265 1483 129 335 1624 168 405 1764 207 1 11 Troubleshooting 1 11 1 Control and Heating Problems Problem Probable Causes Corrective Action A Power cord is not plugged in or circuit breaker is tripped A Plug power cord in and verify that the circuit breaker is not tripped B Contr...

Page 10: ...he problem the most likely cause is a failed temperature probe Fryer heats until high limit trips with heat indicator OFF Contactor controller or element has failed If available substitute a controller known to be working for the suspect controller If the substitute controller functions correctly order a new controller from FASC If the substitution of the controller does not resolve the problem th...

Page 11: ...1 7 1 12 1 Wiring Diagram SR114E Single Phase ...

Page 12: ...1 8 1 12 2 Wiring Diagram SR114E 3 Phase ...

Page 13: ...1 9 1 12 3 Wiring Diagram SR114E WYE ...

Page 14: ...umber Description 1 803 0197 Fryer Friend 27 Cleanout Rod 2 803 0209 Brush Frypot Cleaning 3 809 0171 Thumbscrew 20 X 1 inch Basket Hanger 4 810 2793 Hanger Basket 5 803 0019 Basket Twin 6 803 0132 Basket Support Rack Full Vat 7 826 0900 Kit Chain Restraint for Casters 8 826 1095 Kit Anchor Strap for Legs ...

Page 15: ...2 2 2 2 Cabinetry 2 2 1 Back Base Casters Sides Fluecap Top Cap and Frypot 1 2 3 4 5 6 7 8 9 10 11 12 13 14 16 17 18 15 ...

Page 16: ...338 Valve 1 Universal Ball 14 810 1567 Handle Drain Valve Red w Lock Pin 15 812 1227 Nipple Drain 1 16 810 0356 Caster 5 Wheel w o Brake 826 2003 Mounting Hardware SR114E Casters 809 0428 Screw 20x Hex Head ZP 809 0071 Nut 20 HX ZP 809 0191 Washer Lock Spring ZP 17 810 0357 Caster 5 Wheel w Brake 826 2003 Mounting Hardware SR114E Casters 809 0428 Screw 20x Hex Head ZP 809 0071 Nut 20 HX ZP 809 019...

Page 17: ... Pin Hinge Cover Door 810 0658 Retaining Ring Unplated 2 210 9491 Panel Door 3 210 9544 Bracket Door Hinge 4 809 0083 Rivet Pop Al 1 8 Dia 5 809 0193 Washer Flat Nylon 6 809 0266 Screw 10 Phil TR Head ZP 7 810 0066 Catch Magnetic Door 8 810 0275 Spring Door Hinge 9 810 1422 Handle Door 10 816 0529 Bumper Rubber Self Adhesive 11 816 0630 Cap Vinyl 172 x 500 ...

Page 18: ... Fuse Block Buss 2968 3 Pole 7 807 1683 Relay 12 VDC 8 807 1999 Transformer V T Dual Voltage 208 222 230 240V 9 807 3559 High Limit 435 F w Manual Reset 807 3560 High Limit 410 F 210 C w Manual Reset CE 10 807 4017 Fuse 50 AMP 480VAC 300VDC 11 809 0112 Screw 8 32 x 1 TR SL HD SS 12 809 0117 Screw 10 32 x 3 8 SLTD TR HD SS 13 809 0247 Nut 8 32 HEX KEPS ZP 14 809 0256 Nut KEPS 10 32 HX ZP 15 809 035...

Page 19: ...ing 3 16 CC x NPT Compression 4 Elements 807 4031 Element 208V 14KW 807 4331 Element 220V 14KW 807 4072 Element 240V 14KW 807 4340 Element 230V 14KW 5 210 8392 Clamp Element 6 210 8393 Bracket Mount Hi Limit 7 210 8390 Mount Element Support 809 0518 Screw 8 32 x 3x8 Slotted Head 8 910 5022 Bracket Element Probe 9 807 4110 Cable 3 Phase 4 Wire 208 240V 10 826 2222 Probe Temperature includes compres...

Page 20: ...eport Louisiana 71135 1000 Shipping Address 8700 Line Avenue Shreveport Louisiana 71106 TEL 1 318 865 1711 FAX Parts 1 318 219 7140 FAX Tech Support 1 318 219 7135 PRINTED IN THE UNITED STATES SERVICE HOTLINE 1 800 551 8633 819 6109 FEB 2007 ...