6.6 Load LCIT (
Value)
6.6 Load LCIT (
Value)
Explanation: This message indicates that the 500-sheet LCIT cassette is
empty, is the incorrect size, or is not installed. The three LCIT size sensing
switches detect the size of the installed cassette.
Signal diagram reference: Figure 6–7
Action: Do the following if the message appears intermittently or fails to
clear:
1.
Make sure the 250-sheet internal cassette is fully installed.
2.
Remove and inspect the 500-sheet LCIT cassette. Replace the cassette if
you find any damage. If the cassette is a universal type cassette, make
sure the size sensing cams are set to the correct size.
3.
Manually actuate the size sensing switches. Replace the paper feed control
board if the switches stick, bind, or fail to operate.
4.
Inspect the linkage of the LCIT paper sensor. Replace the LCIT if the
linkage sticks, binds or fails to work properly.
5.
Swap the following FRUs:
•
LCIT controller board
•
LCIT
•
DC control board
•
Paper feed controller board or paper feed assembly
•
Feed unit and option interconnect
6–10 Power and Control Panel FIPs
Summary of Contents for DEClaser 5100
Page 10: ......
Page 13: ...DSG 000172 Notes 1 ...
Page 14: ......
Page 61: ...2 5 HVPSA Figure 2 12 EP ED Cartridge DSG 000612 2 1 3 4 5 6 7 Technical Description 2 25 ...
Page 62: ...2 5 HVPSA DSG 000172 Notes 2 26 Technical Description ...
Page 70: ...3 2 Control Panel Operation DSG 000172 Notes 3 8 Operating the Control Panel ...
Page 90: ......
Page 124: ...7 5 Phantom Jams DSG 000172 Notes 7 8 FIPs for Fixing Paper Jams ...
Page 167: ...9 12 Board DC Control 1 2 4 5 7 8 9 6 3 10 DSG 000657 Removing and Replacing FRUs 9 31 ...
Page 224: ...10 1 Field Replaceable Units DSG 000172 Notes 10 4 FRU Part Numbers ...
Page 254: ...B 4 Connecting to OpenVMS VAX or ULTRIX Systems DSG 000172 Notes B 10 General Information ...
Page 264: ...D 3 Tools DSG 000172 Notes D 4 Training Documentation and Tools ...
Page 274: ......