6.11 All Hard Disk Errors
6.11 All Hard Disk Errors
The following messages are associated with the optional hard disk system. The
disk is installed and formatted by the customer.
Disk Added *
* to format disk
These messages are part of the automatic disk formatting
procedure. See Section 4.11 for more information.
Disk nn% full
This message appears when the disk is at least 70% full.
Disk full
This message appears when the disk is at least 90% full. The
printer stops downline font loading.
Disk Removed *
The printer cannot find a previously installed disk. Press
3
to continue operation.
Disk write error
Disk read error
The disk cannot read or write to a previously good area of the
disk surface.
Disk error
Disk error nnnn
An unknown or known disk error has occurred.
Where:
1218 = Disk access failure
5033 = Master drive format failure
5034 = Master drive buffer failure
5035 = Master drive ECC failure
5036 = Master drive microprocessor failure
5037 = Master drive interface failure
5038 = Slave drive diagnostics failure
1234 = IDE bus busy and unable to send command
1238 = Event time out
5032 = Bad block
5031 = Uncorrectable data
5030 = Identification not found
1228 = Command aborted
5029 = Track 0 not found
5028 = Data Address mark not found
When problems occur with the disk, you must swap the disk or swap the video
controller board. Note any exact error messages in the maintenance log and on
the return tag.
Power and Control Panel FIPs 6–15
Summary of Contents for DEClaser 5100
Page 10: ......
Page 13: ...DSG 000172 Notes 1 ...
Page 14: ......
Page 61: ...2 5 HVPSA Figure 2 12 EP ED Cartridge DSG 000612 2 1 3 4 5 6 7 Technical Description 2 25 ...
Page 62: ...2 5 HVPSA DSG 000172 Notes 2 26 Technical Description ...
Page 70: ...3 2 Control Panel Operation DSG 000172 Notes 3 8 Operating the Control Panel ...
Page 90: ......
Page 124: ...7 5 Phantom Jams DSG 000172 Notes 7 8 FIPs for Fixing Paper Jams ...
Page 167: ...9 12 Board DC Control 1 2 4 5 7 8 9 6 3 10 DSG 000657 Removing and Replacing FRUs 9 31 ...
Page 224: ...10 1 Field Replaceable Units DSG 000172 Notes 10 4 FRU Part Numbers ...
Page 254: ...B 4 Connecting to OpenVMS VAX or ULTRIX Systems DSG 000172 Notes B 10 General Information ...
Page 264: ...D 3 Tools DSG 000172 Notes D 4 Training Documentation and Tools ...
Page 274: ......