VP-3
User’s Manual
4. Connecting Sensors
16
Connecting to a Non-Decagon Logger
The VP-3 sensor may be purchased for use with non-Decagon
data loggers. These sensors typically come pre-configured with
stripped and tinned (pigtail) lead wires for use with screw
terminals. Refer to your distinct logger manual for details on
wiring. Our integrator’s guide gives detailed instructions on
connecting the VP-3 sensor to non-Decagon loggers. Please visit
www.decagon.com/support/literature to reference the complete
integrator’s guide.
Pigtail End Wiring
Connect the wires to the data logger as shown, with the supply
wire (white) connected to the excitation, the digital out wire (red)
to a digital input, the bare ground wire to ground as illustrated
below.
Ground
(Bare)
Data
(Red)
Power
(White)
3.6-15V DC
G
Supply Digital
out
Ground
Datalogger
Digital
In