background image

DMON

12S

 

Hardware

 

Manual

 

for

 

Firmware

 

Version

 

1.1

 

Copyright

 

©

 

2014

 

Decimator

 

Design

 

Pty

 

Ltd,

 

Sydney,

 

Australia

 

6

9.

 

Control

 

/

 

Format

 

Status

 

(Parameter)

 

When

 

an

 

input

 

is

 

detected

 

the

 

DMON

12S

 

will

 

display

 

the

 

format

 

detected

 

in

 

the

 

top

 

left

 

of

 

each

 

window

 

by

 

default

 

unless

 

the

 

location

 

has

 

been

 

modified

 

via

 

the

 

USB

 

Control

 

Panel.

 

When

 

the

 

sub

 

menu

 

is

 

highlighted,

 

press

 

ENTER

 

to

 

toggle

 

through

 

the

 

following

 

selections:

 

1.)

 

Show

 

for

 

5

 

sec

 

2.)

 

Show

 

Always

 

3.)

 

Off

 

 

10.

 

Control

 

/

 

Audio

 

Source

 

ID

 

(Parameter)

 

The

 

Audio

 

Source

 

Identification

 

icon

 

will

 

appear

 

when

 

selecting

 

which

 

window

 

the

 

audio

 

will

 

be

 

passed

 

from

 

to

 

the

 

output

 

when

 

in

 

multi

viewer

 

mode.

 

This

 

option

 

toggles

 

whether

 

the

 

icon

 

is

 

shown

 

to

 

indicate

 

the

 

window

 

source

 

the

 

audio

 

is

 

coming

 

from.

 

This

 

icon

 

appears

 

in

 

front

 

of

 

the

 

Format

 

Status.

 

When

 

the

 

sub

 

menu

 

is

 

highlighted,

 

press

 

ENTER

 

to

 

toggle

 

through

 

the

 

following

 

selections:

 

1.)

 

Show

 

for

 

5

 

sec

 

2.)

 

Show

 

Always

 

3.)

 

Off

 

 

11.

 

Control

 

/

 

Apply

 

Tally

 

to

 

(Parameter)

 

The

 

Apply

 

tally

 

to

 

parameter

 

allows

 

the

 

selection

 

of

 

the

 

3

 

different

 

types

 

of

 

tally

 

indicators.

 

When

 

a

 

tally

 

is

 

triggered

 

it

 

can

 

be

 

displayed

 

as

 

a

 

small

 

box

 

on

 

the

 

bottom

 

left

 

(default

 

position)

 

of

 

the

 

inputs

 

window

 

or

 

as

 

border

 

around

 

the

 

window.

 

The

 

Tally

 

can

 

also

 

fill

 

the

 

outside

 

of

 

the

 

safe

 

action

 

box.

 

When

 

the

 

sub

 

menu

 

is

 

highlighted,

 

press

 

ENTER

 

to

 

toggle

 

through

 

the

 

following

 

selections:

 

1.)

 

Border

 

2.)

 

Out

 

Safe

 

Action

 

3.)

 

Tally

 

Boxes

 

 

11.

 

Control

 

/

 

Tally

 

Transparency

 

(Parameter)

 

The

 

Tally

 

transparency

 

feature

 

changes

 

the

 

transparency

 

of

 

the

 

tally

 

box

 

/

 

border

 

/

 

Outside

 

safe

 

Action.

 

When

 

the

 

sub

 

menu

 

is

 

highlighted,

 

press

 

ENTER

 

to

 

toggle

 

through

 

the

 

following

 

selections:

 

1.)

 

0%

 

2.)

 

25%

 

3.)

 

50%

 

 

Routing:

 

(Has

 

SUB

MENUs)

 

 

Routing  

Window 1 Source   

Input 1 

 

 

Main

 

Menu

 

<==

Sub

 

Menu

 

Parameter

 

Window

 

When

 

highlighted

 

in

 

the

 

Main

 

Menu,

 

press

 

the

 

ENTER

 

button

 

to

 

enter

 

this

 

sub

menu.

   

Press

 

the

 

<

 

and

 

>

 

buttons

 

to

 

move

 

left

 

or

 

right

 

respectively

 

through

 

the

 

12

 

menus

 

below

 

and

 

press

 

the

 

BACK

 

button

 

to

 

go

 

back

 

to

 

the

 

Main

 

Menu

 

when

 

finished.

 

The

 

current

 

value

 

for

 

each

 

Sub

 

Menu

 

is

 

shown

 

in

 

the

 

Parameter

 

Window.

  

 

1.

 

Routing

 

/

 

Window

 

1

 

Source

 

(Parameter)

 

This

 

is

 

the

 

input

 

source

 

for

 

Window

 

1.

 

When

 

the

 

sub

 

menu

 

is

 

highlighted,

 

press

 

the

 

ENTER

 

button

 

to

 

enter

 

this

 

sub

menu.

 

Press

 

the

 

<

 

and

 

>

 

buttons

 

to

 

move

 

left

 

or

 

right

 

through

 

the

 

following

 

sources:

 

1.)

 

Input

 

1

    

(default

 

for

 

Window

 

1)

 

2.)

 

Input

 

2

    

(default

 

for

 

Window

 

2)

 

3.)

 

Input

 

3

    

(default

 

for

 

Window

 

3)

 

4.)

 

Input

 

4

    

(default

 

for

 

Window

 

4)

 

5.)

 

Input

 

5

   

(default

 

for

 

Window

 

5)

 

Summary of Contents for DMON?12S

Page 1: ...ware Manual for Firmware Version 1 1 Copyright 2014 Decimator Design Pty Ltd Sydney Australia 1 DMON 12S 1 to 12 Channel 3G HD SD SDI Multi Viewer with SDI and HDMI outputs Operating Manual for Firmware Version 1 1 ...

Page 2: ... Border Tally boxes allows for up to 4 Tallies per window with Tally Boxes Green Red Blue and Yellow Load and restore Custom Layouts Fast switching between inputs using Full Screen scaling Selectable output format in both Full Screen and Multi Viewer mode Low latency buffering for each input allowing non synchronous inputs Linked 3G HD SD SDI and HDMI outputs 12 x 3G HD SD SDI inputs with auto det...

Page 3: ...ging parameters they will be instantly applied to the output signal Input Status Has 3 states When pressing enter in the Input Status menu will cycle between the status for input 1 4 5 8 and 9 12 Default 1 3G 1080p59 94 2 HD 720p50 3 SD 480i59 94 4 HD 1080i59 94 Current format on SDI Input 1 Current format on SDI Input 2 Current format on SDI Input 3 Current format on SDI Input 4 After pressing EN...

Page 4: ...is sub menu Press the and buttons to move left or right through the following sources 1 Multi View 2 Window 1 3 Window 2 4 Window 3 5 Window 4 6 Window 5 7 Window 6 8 Window 7 9 Window 8 10 Window 9 11 Window 10 12 Window 11 13 Window 12 3 Control MV Output Format Parameter This is the current output format for the Multi Viewer When the sub menu is highlighted press the ENTER button to enter this ...

Page 5: ...uts attached to this setting Full Screen Pass through will also use the selected layout for 1 window 6 Control MV Audio Source Parameter This selects which window the audio is extracted from for the Multi Viewer output When the sub menu is highlighted press the ENTER button to enter this sub menu Press the and buttons to move left or right through the following sources 1 Window 1 2 Window 2 3 Wind...

Page 6: ...box on the bottom left default position of the inputs window or as border around the window The Tally can also fill the outside of the safe action box When the sub menu is highlighted press ENTER to toggle through the following selections 1 Border 2 Out Safe Action 3 Tally Boxes 11 Control Tally Transparency Parameter The Tally transparency feature changes the transparency of the tally box border ...

Page 7: ...o move left or right respectively through the 10 menus below and press the BACK button to go back to the Main Menu when finished The current value for each Sub Menu is shown in the Parameter Window 1 Colours Background Colour Parameter This is background colour for the Multi Viewer When the sub menu is highlighted press the ENTER button to enter this sub menu Press the and buttons to move left or ...

Page 8: ...lours 1 None 10 Black Transparent 25 19 Blue Transparent 0 2 Black Transparent 50 11 Blue Transparent 25 20 Green Transparent 0 3 Blue Transparent 50 12 Green Transparent 25 21 Cyan Transparent 0 4 Green Transparent 50 13 Cyan Transparent 25 22 Red Transparent 0 5 Cyan Transparent 50 14 Red Transparent 25 23 Magenta Transparent 0 6 Red Transparent 50 15 Magenta Transparent 25 24 Yellow Transparent...

Page 9: ...lowing colours 1 None 10 Black Transparent 25 19 Blue Transparent 0 2 Black Transparent 50 11 Blue Transparent 25 20 Green Transparent 0 3 Blue Transparent 50 12 Green Transparent 25 21 Cyan Transparent 0 4 Green Transparent 50 13 Cyan Transparent 25 22 Red Transparent 0 5 Cyan Transparent 50 14 Red Transparent 25 23 Magenta Transparent 0 6 Red Transparent 50 15 Magenta Transparent 25 24 Yellow Tr...

Page 10: ...ransparent 25 19 Blue Transparent 0 2 Black Transparent 50 11 Blue Transparent 25 20 Green Transparent 0 3 Blue Transparent 50 12 Green Transparent 25 21 Cyan Transparent 0 4 Green Transparent 50 13 Cyan Transparent 25 22 Red Transparent 0 5 Cyan Transparent 50 14 Red Transparent 25 23 Magenta Transparent 0 6 Red Transparent 50 15 Magenta Transparent 25 24 Yellow Transparent 0 7 Magenta Transparen...

Page 11: ...rlays off 3 Audio Meter Combination Parameter This is the combination of either bar or float meters When the sub menu is highlighted press ENTER to toggle through the following selections 1 None 2 Bar Only 3 Float Only 4 Bar and Float 4 Audio Meter Transparency Parameter This is the transparency level of the audio meter overlays When the sub menu is highlighted press ENTER to toggle through the fo...

Page 12: ...vel from 0 to 100dBFS respectively Press the BACK button to leave this SUB MENU 11 Audio Meter Green Start Has SUB MENU with parameter This is the starting level for the green range on the audio meter The value default is 20dBFS When the sub menu is highlighted press the ENTER button to enter this sub menu Press the and buttons to increase and decrease the level from 0 to 100dBFS respectively Pres...

Page 13: ...Has SUB MENUs GPI GPI Mode 00 Main Menu Sub Menu Parameter Window When highlighted in the Main Menu press the ENTER button to enter this sub menu When the sub menu is highlighted press ENTER to toggle through the Modes and press the BACK button to go back to the Main Menu when finished The current value for each Sub Menu is shown in the Parameter Window GPI Mode 00 PIN 1 Ground PIN 14 Window 11 Ta...

Page 14: ...en Setup Has SUB MENUs Setup LOAD DEFAULTS Main Menu Sub Menu Parameter Window When highlighted in the Main Menu press the ENTER button to enter this sub menu Press the and buttons to move left or right respectively through the 6 menus below and press the BACK button to go back to the Main Menu when finished The current value for each Sub Menu is shown in the Parameter Window unless it is an actio...

Page 15: ...lighted press the ENTER button to enter this sub menu Press the and buttons to move left or right through the following cycle types 1 None 2 Output Select 3 MV Windows 4 MV Layouts Note The parameter will only be updated when leaving this sub menu 6 SETUP Demo Cycle Time Parameter The Demo Cycle Time determines the amount of time to elapse before cycling to the next item When the sub menu is highl...

Page 16: ...hipping charges prepaid Decimator Design shall pay for the return of the product to the Customer if the shipment is to a location within the country in which the Decimator Design service centre is located The Customer shall be responsible for paying all shipping charges insurance duties taxes and any other charges for products returned to any other location This warranty shall not apply to any def...

Reviews: