Error Identification
0097 to 0099 Host Support Error Codes
Refer to the following chart if the error code displayed is in the range from 0097 through
0099.
Note
: When one of these codes is displayed, the required host support will not be available.
Host Support Error Code Chart
Error Code
Description and Suggested Recovery
0097
Test Request Function Not Supported. Contact host system operator and
determine why the function is not supported.
0098
Undefined Hardware Error
To recover - press the Error Reset key.
0099
Host Support Not Currently Available
To recover - press the Error Reset key.
100000 to 101D00 X.25 Error Codes
When a keyboard entry error occurs while in X.25 Communication mode, a six-digit error
code between 100000 and 10FFFF is displayed. Error codes along with a short description
and suggested recovery action(s) are listed below:
For errors 100200 - check the system configuration. If the settings match, press the
ERROR RESET
key, check options and repeat the operation. Refer to Host Access Section
for procedure on restarting communications. If this too fails, call your System Operator.
Error
Code
Description and Suggested Recovery
100000
Previous CALL command in progress. Wait until the previous call is complete, or an
error code other than 100000 is displayed.
100100
Virtual circuit already established. Wait for the virtual circuit to be detached before
trying CALL/OPEN commands. It is possible to communicate over one virtual circuit
at a time.
100200
ANSWER command entered for a PVC - Permanent Virtual Circuit`.
100300
CALL command entered for a PVC - Permanent Virtual Circuit
100400
Invalid logical channel ID.
(Less than 3 characters long)
100500
Invalid logical channel ID.
(Not a hexadecimal value between 001 and FFF).
100600
Invalid password. (More than 8 characters)