Host Connections
attached workstation. Valid values = [1 to
255] milliseconds; default value = 30
Retry Counter
Maximum number of retries to perform
checkpoint procedure, after the
Response
Timer
has timed out. the value is the
Response Time (X) Retry counter = Total.
The total must allow for error detection and
recovery. Valid values are 1 to 99 retries;
default value is = 8
4.2PU Connections to Host
The Model 3494 Controller supports up to eight logical PUs. At least one PU should be
defined for each line connection assigned to the AS/400. The number of devices per line
can be increased by defining more than one PU for a line.
The PU connections to host are configured as follows:
•
Assign each PU a specific communication line (X.25, SDLC, Token Ring or Ethernet)
•
Assign each PU an address
Assigning the PU Communication Lines
1. Access the 3494 Main Setup menu.
2. Select the Controller Configuration option. The following screen appears:
3. To enable a PU, define the line number to which it is connected. If you do not wish to
enable a particular PU, define it as Disable.
9