Network Information
For X.25 Connection
Connection Number
If you intend to initiate SVC calls from the controller or want
to verify incoming SVC calls using a network address, an
entry is required here. For X.25 - The Network Address of
the AS/400 System. Up to 15 numeric characters (0-9).
Password
This is the X.25 network connection password. This is
relevant for SVC circuit types that include outgoing calls.
This password must match the configured password on the
AS/400 System. All alphanumeric keyboard characters are
valid, up to 8 characters. If fewer than 8 characters are
entered, enter 0 for the remaining spaces.
Logical Channel
identification
This value is used to override the configuration value for this
circuit request only. This value is 0001 unless changed.
Valid characters are 0-9 in the range '0001' to '4095'.
For Token-Ring Attachment
Connection Number
This parameter MUST be defined for Token Ring
communication, this is the AS/400 Token-Ring adapter’s
MAC address.
Enter the 12-character hexadecimal Token-Ring address.
Valid characters are 0-9, and A-F (upper case).
AS/400 system SAP
Enter the Service Access Point (SAP) for the AS/400.
The value is in hexadecimal ranging from x'04' to x ‘FC',
in multiples of 04.
For example, valid values could be x'04', x'08', x'0C', and
so on.
Valid characters are 0-9 and A-F (upper case).
Configuring for more than one AS/400 system (systems
2-4) is optional
Maximum Out
Enter the Maximum Out value for the AS/400. This value
is the maximum number of frames sent by the controller
before waiting for an acknowledgment. The minimum
value must be at least twice the Maximum In value
Valid values are 2-8 frames. Default is ‘2’
7