Network Information
Maximum In
Enter the Maximum In value for the AS/400. This value
is the maximum number of frames received by the
controller before it sends an acknowledgment.
Valid values are 1-4 frames. Default is 1.
For Ethernet Attachment
Address format
The address could be entered in Ethernet format ( 0 ) or Token-
Ring format ( 1 ). Default is Ethernet format.
Connection
Number
This parameter MUST be defined for Ethernet communication, this
is the AS/400 Ethernet adapter’s MAC address.
Enter the 12-character hexadecimal Ethernet address Valid
characters are 0-9, and A-F (upper case).
AS/400 SAP
Enter the Service Access Point (SAP) for the AS/400. The value is
in hexadecimal ranging from x'04' to X ‘FC', in multiples of 04.
For example, valid values could be x'04', x'08', x'0C', and so on.
Valid characters are 0-9 and A-F (upper case). Configuring for
more than one AS/400 system (systems 2-4) is optional
Maximum Out
Enter the Maximum Out value for the AS/400. This value is the
maximum number of frames sent by the controller before waiting for
an acknowledgment. The minimum value must be at least twice the
Maximum In value
Valid values are 2-8 frames. Default is 2
Maximum In
Enter the Maximum In value for the AS/400. This value is the
maximum number of frames received by the controller before it
sends an acknowledgment
Valid values are 1-4 frames. Default is 1.