6Gateway Configuration
The 3494 Controller supports gateway configuration for Token Ring or Ethernet attachment.
The LAN adapter (Ethernet or Token-Ring) enables support of up to 80 PWSs.
REMINDER:
The Controller can be configured as either Token-Ring line or Gateway - not
as both. To define it as Gateway ensure that it is DISABLED as Token-Ring line in the Line
Type Selection screen (see Chapter 3).
6.1Token Ring Gateway
For Token Ring Gateway configuration access the 3494 - Setup menu and enter
option (6)
Gateway Configuration
. The Gateway menu appears. Define the parameters according to
the given parameter explanations.
PU number
Specifies the Physical Unit (PU) which the Token-Ring attached PWSs
are connected to. Since PC support devices are not assigned sessions
and are not displayed in the PU/LSID map, this parameter is added to
specify the PU which the PC’s are connected to. Enabled PU’s are
displayed near the parameters.
Valid values are 1 to 8. Default is 1. Select an active PU.
Data Transfer
rate
The Data Transfer Rate can be either 4 or 16 MB Per Second. Default is
1