AS/400 System Configuration
Attributes configured manually:
1. Line type.
2. APPC Controller
3. RWS Controller.
4. Device description for each NWS attached to the RWS controller.
To view the modes defined in the AS/400 System:
1. Type "WRKMODD", to display the modes.
2. Choose Option-5, to view the attributes of each displayed mode.
The following table lists the matching AS/400 and Controller attributes.
AS/400 Attributes
Controller Attributes
1. Local network ID
AS/400 network name
2. Default Local location
AS/400 LU name
3. Remote control point
3494 control point (CU) name
4. Remote location name
3494 logical unit (LU) name
5. One of the mode names defined
in the AS/400
Default Mode name, and AS/400 System
mode name
AS/400 parameters required for the 3494 Controller configuration comprise of the
following three types:
1. Communication Information.
2. Network Addresses (X.25, Ethernet and Token-Ring only)
3. APPN Information
9.1.1Mode Description
The MODE name determines:
•
number of NWS sessions
•
maximum frame size
•
pacing value
The mode name "QRMTWSC", is supplied by IBM Version 2 Release 2. It defines 28 NWS
sessions and pacing value of seven.
If you want to create a new Mode, type the command: CRTMODD
2
Summary of Contents for 3000 Series
Page 1: ...Series 3000 STK3494 3494 User s Manual ...
Page 2: ......