is inactive. (except during V.25 bis call establishment).
0051
Transmit Clock Failure. The transmit clock failed during a transmit operation.
0052
Transmit Hardware Error. The link adapter hardware failed to complete a transmit
operation within 30 seconds, but no transmit clock or other DCE signal failure was
detected.
0053
Expiration of Retry Count (X.25 only). No acknowledgment of a transmission was received
within allowed timeout. (Timeout retry count (N2) and retry interval (T1) are specified in
CSU Field 7)
0054
Frame Reject Sent. The control unit has sent a link-level FRMR response to the host
system after receiving an invalid SDLC or LAPB command. Sense bytes S1, S2 and S3
preserve the contents of the FRMR I-field.
0060 to 0069 Ideographic Errors
0060
Ideographic or Bidirectional support error. Invalid data or key pressed. To correct error,
press Error-Reset at the work station and if it is an Ideographic error, this field only accepts
double-data characters--enter the correct data.
0061
Ideographic or Bidirectional support error. Invalid data or key pressed. To correct error,
press Error-Reset at the work station and if it is an Ideographic error, this field only accepts
alphanumeric data--enter the correct data.
0062
The cursor is not in position to change the data type. Press Error-Reset and re-attempt.
0063
Invalid Ideographic character entered in Alternate Entry mode. Press Error-Reset.
0064
The keyboard mode does not support the key pressed. Press Error-Reset.
0065
The cursor is in a column reserved for shift-out or shift-in characters. Press Error-Reset.
0066
This is not a data character and therefore, cannot be repeated. Press Error-reset.
0067
The workstation extension character RAM is full. Press Error-Reset.
0068
The output data stream to the 3030 is not valid for extension characters. Press Error-
Reset.
0069
Ideographic or Bidirectional support error. Ideographic error--The extension characters to
the 3030 are undefined; Bi-directional error--a terminating character cannot be inserted.
Press Error-Reset.
A-
11
Summary of Contents for 3000 Series
Page 1: ...Series 3000 STK3494 3494 User s Manual ...
Page 2: ......