background image

 

Decoflame ApS  Danmark. ~ info@decoflame.dk 

 ~ tel. +45 96 3048 00 ~ 

 

OPERATING INSTRUCTIONS 
 

decoflame® Denver S 

 

            decoflame® Denver F 

 

 

Your decoflame

®

 fireplace with e-Ribbon Fire has a built-in child safety ON/OFF switch which is located 

underneath the pop-up lid of the LED-display. 

ALWAYS 

start operation of your decoflame

®

 fireplace using its 

built-in automatic by switching it on (push down onto the pop-up lid to the left, flip it over and switch the 
ON/OFF button into the ON position) and then start the ignition process by pressing the START button either 
on the remote control or on the operating panel next . 

DO NOT

 use lighters or matches. 

ONLY

 adults may 

operate the electronics of the decoflame

®

 e-ribbon Fire. 

All decoflame

®

 bioethanol fireplaces are designed and manufactured exclusively for use with bioethanol of 

highest purity (96%). 

DO NOT

 use any other fuel or materials or bioethanol of inferior quality as this will void 

your warranty. Bioethanol can be bought in specialist shops or on the internet – ask your decoflame

®

 point of 

sale for advice. 

Switching on 

Start the electronics of your decoflame

® 

e-ribbon Fire by pushing down onto the pop-up lid to the left, flipping 

it over and switching the ON/OFF button into the ON position. Flip the lid back so that the LED-display is fully 
visible. The first line of the LED-display will show the message READY or FUEL LOW, the second line 
indicates the fuel level. 

 

LED-display and Use of Remote Control 

The LED-display will always show the following – 
Line 1: 

Flame level or message (e.g. READY, FLAME 3 or FUEL LOW

Line 2: 

Fuel level indicator bar 

 
During operation of the fire, you could close the pop-up lid of the LED-display completely by pressing down 
onto it until you hear a soft “click” sound. You can still use the remote control in order to change the flame 
level settings or to shut down the fire, despite the display being invisible. 

 
Filling of the Fuel Tank 
 – First time fuelling 

Switch on the electronics of the fireplace as described above. The display will show the message READY or 
FUEL LOW. 
Push down onto the pop-up lid to the right. Open the fuel tank inlet by pulling the closing 
mechanism towards you. Insert a funnel and fill in the bioethanol. Once the fuel tank is filled by three-
quarters, you will hear an acoustic signal. This tone will increase in line with the rising fuel level. Once the 
tank is completely filled, a constant tone will sound. Stop the filling process. Avoid spillage during filling. If 
you spilled any bioethanol, use a paper kitchen towel in order to wipe off thoroughly any spilled liquid around 
the fuel inlet. Remove the funnel. Close the pop-up lid for the tank inlet.  
 

NB: Do not fill the bioethanol tank whilst the electronics of the fireplace are switched off. 
 
NB: The ignition process will not start if any humidity is detected around the fuel inlet or if the pop-
up lid for the tank inlet is left open. 

LED-display 

base plate 

ventilation slots 

fuel inlet 

housing 

flame tray 

fuel inlet 

LED-display 

ventilation slots 

 

 

power cable 

power cable 

flame tray 

housing 

base plate 

Summary of Contents for Denver

Page 1: ...nd Denver with decoflame e ribbon Fire featuring CEVB Technology English Decoflame Aps Stenholm 14 9400 Nørresundby Denmark tel 45 96 30 48 00 info decoflame dk www decoflame com It is imperative that you read this manual before using the fireplace Keep the manual in a safe place for future reference ...

Page 2: ...NS TABLE OF CONTENT GENERAL SAFETY 2 POSITIONING 3 MAINTENANCE 3 INSTALLATION 4 OPERATING INSTRUCTIONS 6 MESSAGES ON LED DISPLAY AND TROUBLESHOOTING ADVICE 8 SAFETY ADVICE 9 DISPOSAL AND RECYCLING 9 RATING PLATE INFORMATION 9 GENERAL SAFETY Naturally safety is imperative dealing with open fire All decoflame fireplaces are designed manufactured and quality tested in Denmark with highest product saf...

Page 3: ... your custom made fireplace are perfectly in level and all corners of the cut out are in a perfect 90 degree angle For all dimensions please refer to the detailed technical drawing for your decoflame fireplace If in doubt please contact Decoflame If your fireplace is installed in a room with a wooden ceiling you must ensure that the distance between the top of the fireplace and the ceiling is at l...

Page 4: ... needs a connection to the mains in order to work Therefore a power socket needs to be present inside the cut out into which the fireplace will be fitted When installing your decoflame built in fireplace you will need Power drill Screwdriver Drill bit suitable for the type of material to which you wish to fix the top and bottom plates of your fireplace Spirit level Tape measure Screws at least Ø 5...

Page 5: ...e to the highest possible finish All four corners of the cut out must have an exact 90 degree angle Denver drop down e Ribbon Fire The distance between the flame tray and any non flammable material above must not be less than 500mm The distance between the centre of the flame tray and any non flammable material to the back or front must not be less than 150mm DO NOT position the Denver in a draugh...

Page 6: ...d Use of Remote Control The LED display will always show the following Line 1 Flame level or message e g READY FLAME 3 or FUEL LOW Line 2 Fuel level indicator bar During operation of the fire you could close the pop up lid of the LED display completely by pressing down onto it until you hear a soft click sound You can still use the remote control in order to change the flame level settings or to s...

Page 7: ...ray is filled with flames depending on the dimensions of the flame tray it might take slightly longer Once the flame tray shows flames throughout its complete width the fire will be burning at a pre set level of 3 as long as the message WARMING UP is shown in the display this pre set level cannot be changed As soon as the warming up phase is finished the message FLAME 3 is shown in the display and...

Page 8: ...emperature which is too high inside the housing of the e Ribbon Fire Make sure that the ventilation slots around the flame tray are not obstructed do not place ceramic logs or pebbles there Also check that the fireplace has been installed with the necessary 5mm gap all the way around and below the base plate models Montreal and Orlando If you find that all is at it should be call your point of sal...

Page 9: ... at an adequate level by opening a window or door ever once in awhile during operation of your fire This can be achieved by opening a window for around 5 10 minutes or by leaving doors to adjacent rooms open Should the premises in which the fire is situated be equipped with an MVHR System Mechanical Ventilation with Heat Recovery the room air quality will automatically be kept at a high level and ...

Page 10: ...10 Decoflame ApS Danmark info decoflame dk tel 45 96 3048 00 For more information please visit www decoflame com or contact Decoflame at info decoflame dk ...

Reviews: