Instruction manual 

 

Water Management Boiler System C 110 L 110V 

 

 

 

 

 

Seite 4 

 

2 Transport and storage 

 

2.1 Delivery 

 
If no other agreements have been made, the unit is packed safely and will be delivered 
ex work. Transport damages have to be immediately documented by the carrier or 
another supplier. Please also note the possible damages on the way bill.  
 

2.2 Transport

 

 
The Transport is to be proceeded with care to avoid damages by improper handling or 
carelessness.  
It is important to avoid exposure to violent shocks, otherwise the function and safety of 
the unit cannot be guaranteed. In winter and at risk of frost, the whole unit (Pump, filter 
housing and tank) needs to be emptied before transport.  

Attention:

 Transport of unit (also relocation) only when empty. 

 

2.3 Storage 

 
In order to avoid damages, the installation has to be kept in a dry area with no access for 
unauthorized persons. 
 

Because of risk of frost in winter it is important to observe the following: 

  Empty water hoses, filter housing, tank and pumps 

  Place Water Management in a frost-protected area 

 

Advice for the draining of the tank

:To drain remove cap “empty tank“ and tilt valve.  

 

 

Cap 

Valve 

Summary of Contents for C110 L 110V

Page 1: ...Instruction manual Water Management System C 110 L 110V Manufacturer deconta GmbH Im Geer 20 D 46419 Isselburg Description Water Management System C 110 L 110V Type No 602 Serial No...

Page 2: ...ery 4 2 2 Transport 4 2 3 Storage 4 3 Volume of delivery 5 4 Technical description 5 4 1 Intended use 5 4 2 Unit description 5 5 Technical data 6 6 Initial operation 7 7 Maintenance and care 9 7 1 Dai...

Page 3: ...e event of non observance deconta assumes no liability To ensure safety during operation of the unit the following must be strictly observed Do not use in potentially explosive areas Necessary repairs...

Page 4: ...nt to avoid exposure to violent shocks otherwise the function and safety of the unit cannot be guaranteed In winter and at risk of frost the whole unit Pump filter housing and tank needs to be emptied...

Page 5: ...During asbestos sanitation works within closed rooms you have to exclude that the asbestos fibres leave the sanitation area uncontrolled and endanger the human health and the environment For this rea...

Page 6: ...e service water 110 Liter Tank filling automatic or manually via filling port Heating capacity 1000 W Filter stages 3 Filter size 10 Power connection 100 120 V Power consumption 7 A Water connections...

Page 7: ...etwork or fill manually via filling port o Connection Warm water shower water with shower top o Connection Sewage IN with shower tray o Connection Sewage OUT with sewage system Connect to power supply...

Page 8: ...tion Shower water pump waste water pump and heating rod active Safety instructions During works on the device always disconnect the plug Operate the device only with mains which are secured with fault...

Page 9: ...r dirt Control of fine filter via manometer 7 2 Filter change The Manometer controls the fine filter We recommend a filter change at approx 3bar Attention Change Filter only when device is switched of...

Page 10: ...e first use Repairs and maintenance may only be executed under the observance of all relevant safety measures All the filters mentioned have to be disposed of according to the legal terms 7 3 Reductio...

Page 11: ...move hoses Remove fastening screw of pressure switch ATTENTION Do not alter the middle adjusting screw Remove fastening screw of pump head and take off the head Remove Valve plate and clean on front a...

Page 12: ...Instruction manual Water Management Boiler System C 110 L 110V Seite 12 8 Circuit diagram...

Page 13: ...GmbH Im Geer 20 D 46419 Isselburg Product Water Management C 110 L Type 602 The design of the unit complies with EU Machine directive 2006 42 EG the following directives EU Low voltage directive 2006...

Reviews: