background image

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

7300 Industry Drive, North Little Rock, AR 72117 

Phone: 501-955-2929 Fax: 501-955-2988 

www.decraneaerospace.com

 

 

Installation Manual 

 

LCD-9084-301-x 

 

8.4" Flat Panel LCD Monitor  

 

Document # 540332 

Summary of Contents for lcd-9084-301-x

Page 1: ...7300 Industry Drive North Little Rock AR 72117 Phone 501 955 2929 Fax 501 955 2988 www decraneaerospace com Installation Manual LCD 9084 301 x 8 4 Flat Panel LCD Monitor Document 540332 ...

Page 2: ...nnector from DAMA 15P to DEMA15PK87 Section 3 6 Troubleshooting and Continued Airworthiness are now separate sections Sections 4 0 5 0 Removed every 3 months from Section 4 1 conflicted with No periodic scheduled maintenance in Section 5 0 Added Housing info to Unit Specifications Section 6 1 Corrected SP LCD6 dimensions for cutout Section 6 2 Added center points of gravity and measurements to bac...

Page 3: ...5 3 1 Prior to Installation 5 3 2 Unpacking and Inspection 6 3 3 Cautions Warnings 6 3 4 Wiring Requirements 7 3 5 Electrical Characteristics 9 3 6 Mating Connector Information 11 3 7 Pinout Assignment Descriptions 12 3 8 SP LCD6 Configuration Overview 13 4 0 Troubleshooting 13 4 1 Cleaning Method 13 4 2 General Troubleshooting Procedures 14 4 3 Troubleshooting Chart 15 5 0 Instructions for Contin...

Page 4: ...nd fast response time with no distortion or smearing The monitor is designed for bulkhead mounting 1 3 Optional Equipment DeCrane Aerospace Audio International offers a comprehensive family of Cabin Control Modules and Source Equipment such as DVD players integrated touch screens speakers and other equipment that will perfectly complement the LCD 9084 301 x and will be valuable and attractive addi...

Page 5: ...se that both Composite and VGA are applied the monitor defaults to the VGA input The user can switch between inputs or set video input priority using the On Screen Display see Section 3 8 2 2 Communication This unit incorporates an RS 485 serial data bus interface for communication purposes to other network connected devices All RS 485 serial data bus electronic interface parameters are compliant ...

Page 6: ...sed on the data bus 2 4 5 The monitor casing is specially designed for EMI and noise filtering guaranteeing a reduction in interference to ensure a high quality display 2 4 6 A shallow mounting depth makes this monitor ideal for bulkhead use Convenient mounting holes are strategically located on the left and right sides An optional front cover bezel see Section 1 3 may be purchased for added mount...

Page 7: ...1 model monitor 3 1 7 The maximum length of the connection to PC Graphic VGA input is 15 feet 3 2 Unpacking and Inspection 3 2 1 Carefully open the packaging and remove the LCD 9084 301 x Verify that all components have been included in the package per the packing list Inspect the unit for damage Retain the packing materials and packing list 3 2 2 If damage has occurred during shipping a claim sho...

Page 8: ...ling agency shall supply and fabricate all external cables and mating connectors The length and routing of external cables should be carefully studied and planned before attempting installation of the equipment Allow adequate space for installation of cable and connectors Avoid sharp bends and placing cables near aircraft control cables Maintain a minimum clearance of three 3 inches from any contr...

Page 9: ... the LCD 9084 301 x Serial digital video connections are recommended to use shielded coaxial cable in accordance with PIC V76261 or equivalent 3 4 4 RS 485 Connections RS 485 connections shall be twisted shielded cable with the shield properly grounded at the source ideal practice and floating at the load end If shield cannot be grounded at the source then ground at the load end with the source en...

Page 10: ...50 C Storage Temperature 4 to 158 F 20 to 70 C Composite Video Input 1 V p p 75 Component RGB Input Industry Standard Digital Video Input ANSI SMPTE 259M 1997 3 5 2 Electrical Specifications SP LCD6 Electrical Power 80 mA at 28 VDC maximum Switch Backlighting Green Mounting Studs 6 32 x 0 75 inches long 3 5 3 The LCD 9084 301 x utilizes three 3 connectors J1 is a 13 pin connector that provides pow...

Page 11: ...a bus control Three 3 ID pins are also provided on the J2 connector These ID pins allow for up to eight 8 units to be connected on the same DAAI proprietary RS 485 data bus while maintaining independent control of each unit Depending upon the necessary configuration the ID 0 ID 1 and ID 2 pins shall connect to the ID common as suggested below ID 2 ID 1 ID 0 No of Units 1 1 1 1 1 1 0 2 1 0 1 3 1 0 ...

Page 12: ...J2 CONNECTOR PART NUMBER MATING CONNECTOR LCD 9084 301 1 RD9M10JVL0 Female Plug or equivalent Positronic Industries LCD 9084 301 2 DEMA 9P Female Plug w male jackscrews or equivalent ITT Cannon J3 CONNECTOR PART NUMBER MATING CONNECTOR LCD 9084 301 1 DD15M10JVL0 Male Plug or equivalent Positronic Industries LCD 9084 301 2 DEMA15PK87 Male Plug w male jackscrews or equivalent ITT Cannon 3 7 Pinout A...

Page 13: ... Common J3 Pin Description 1 Red Video 2 Green Video 3 Blue Video 4 Reserved 5 Ground 6 Red Ground 7 Green Ground 8 Blue Ground 9 Key 10 Sync Ground 11 Reserved 12 Reserved 13 Horizontal Sync 14 Vertical Sync 15 Reserved 3 7 2 Wiring description for the SP LCD6 is as follows SP LCD6 Pin Description 1 28 VDC Power Input 2 Power Ground 3 Serial Data Bus A HI 4 Serial Data Bus B LO 5 Serial Data Bus ...

Page 14: ...tor defaults out of menu mode 2 BACKLIGHT Backlighting intensity 3 FACTORY PRESET All modes may be reset to the default factory setting Select either YES or NO 4 SOURCE PRIORITY Selects priority operating mode to PC personal computer or None Setting this mode to PC allows user to normally view composite video until a PC laptop is turned on then the monitor will automatically switch to PC input upo...

Page 15: ...g 28 VDC power is applied to the proper pins on the unit Use a voltmeter to verify correct level Remove power from the unit for at least one 1 minute and reapply power Recheck all connections to the unit for security Check all harness runs for possible pinching Recheck all pinouts for application accuracy Check data bus integrity by utilizing a voltmeter oscilloscope or other voltage instrument to...

Page 16: ...cheduled maintenance or calibration is required for continued airworthiness of the LCD 9084 301 x If the unit fails to perform to specifications it must be removed and serviced by a qualified service facility 6 0 Specifications 6 1 Unit Specifications for LCD 9084 301 x Physical Specifications LCD 9084 301 x Screen Size 8 4 21 34 cm diagonal Housing Iridited Aluminum with black powder coat finish ...

Page 17: ...D 9084 301 x Installation Manual Document 540332 Rev A 01 2009 Page 16 of 18 7 0 Reference Drawings 7 1 LCD 9084 301 x The following diagrams show the unit dimensions mounting locations and connector locations for the LCD 9084 301 x J2 J1 J3 ...

Page 18: ...DeCrane Aerospace Audio International LCD 9084 301 x Installation Manual Document 540332 Rev A 01 2009 Page 17 of 18 ...

Page 19: ...national LCD 9084 301 x Installation Manual Document 540332 Rev A 01 2009 Page 18 of 18 7 2 External Menu Switch The following diagrams show the unit dimensions and connector locations for the external menu selection switch SP LCD6 ...

Reviews: