DeCrane Aerospace Audio International
LCD-9084-301-x Installation Manual
Document # 540332, Rev A, 01/2009
Page 13 of 18
3.8
SP-LCD6 Configuration Overview
Configuration is typically accomplished via an SP-LCD6 attached to the
D-Subminiature connector on the monitor. DeCrane Aerospace Audio
International reserves the right to add, delete, or alter functions from the
setup menus without advance notification to the user. To access the Main
Menu, press the “MENU 1” button, which will cause the Monitor setup
menu to be displayed on the LCD-9084-301-x. To scroll through the setup
modes, press the “MENU 2” button to scroll forward or the “MENU1”
button to scroll back. When in the desired mode for setup monitor, press
either LEFT (-) or RIGHT (+) to change the selected value. Pressing the
LEFT button decreases the selected value and pressing the RIGHT button
increases the selected value. Press the appropriate button for the desired
adjustment. Press the “MENU 2” button to scroll to the next menu option.
A typical Monitor Setup Menu consists of the following modes
:
1. “OSD TIMEOUT”- Timeout period until monitor defaults out of menu mode.
2. “BACKLIGHT”- Backlighting intensity.
3. “FACTORY PRESET”- All modes may be reset to the default factory setting. Select
either “YES” or “NO”.
4. “SOURCE PRIORITY”- Selects priority operating mode to “PC” (personal computer)
or “None”. Setting this mode to “PC” allows user to normally view composite video
until a PC laptop is turned on, then the monitor will automatically switch to PC input
upon sensing VGA input.
5. “H-POS”- Adjusts viewing area horizontally.
6. “V-POS”- Adjusts viewing area vertically.
7. “SHARPNESS”- Adjusts picture sharpness.
8. “COLOR”- Adjusts picture color.
9. “TINT”- Adjusts picture tint.
10. “CONTRAST”- Adjusts picture contrast.
11. “BRIGHT”- Adjusts picture brightness.
The setup menu may vary slightly from monitor model to model. As
technology advances, additional features may be added to the setup
menu and existing features may be modified. DeCrane Aerospace Audio
International’s intention is to provide clear and concise instructions on any
new or modified feature in the setup menu as these changes occur.
4.0
Troubleshooting
4.1
Cleaning Method
The LCD-9084-301-x should be cleaned when excessive dust or dirt
becomes apparent.
Use a twin pack cleaning system that employs a wet pad pre-moistened
with an Isopropyl Alcohol based cleaner/anti-static solution and a lint-free