DeCrane Aerospace Audio International
LCD-9084-301-x Installation Manual
Document # 540332, Rev A, 01/2009
Page 6 of 18
(60.96 cm) in length ±1 inch (2.54 cm) and has 6-32 x 0.75 inch
mounting studs. Refer to Sections 6.0 and 7.2 for the adjustment
switch characteristics.
3.1.4 Mounting provisions are provided via eight (8) 8-32 UNF-2B, on the
left and right sides, four (4) one each side. The maximum depth
should be no more than 0.38 inches. Refer to Section 7.0,
Reference Drawings, for mounting hole diameters and
configuration.
3.1.5 The monitor should be located as close to the source equipment as
possible in order to reduce the possibility of noise introduced into
the video. Refer to Section 7.0 for unit dimensions.
3.1.6 The LCD-9084-301-x is configured using the external menu
selection switch, SP-LCD6. The switch utilizes a D-Subminiature
connector. This connector mates with the D-Subminiature
connector on the LCD-9084-301-1 model monitor.
3.1.7 The maximum length of the connection to PC Graphic (VGA) input
is 15 feet.
3.2 Unpacking and Inspection
3.2.1 Carefully open the packaging and remove the LCD-9084-301-x.
Verify that all components have been included in the package per
the packing list. Inspect the unit for damage. Retain the packing
materials and packing list.
3.2.2 If damage has occurred during shipping, a claim should be filed
with DeCrane Aerospace Audio International WITHIN 24 hours and
a
Return Request Authorization Number
shall be obtained from
DAAI by contacting the Repair Department at 501.801.8101.
Repackage the unit in its original packaging materials and return it
to DAAI following instructions given by the DAAI representative.
Refer to the front cover of this manual for address. If no return is
necessary, retain the packing list and the packing materials for
storage.
3.3
Cautions and Warnings
3.3.1 It is important to do a pin-to-pin power and ground check on all
connectors. Ensure that power and ground are applied only where
specified. Damage to the unit may result if power or ground is
applied to the wrong points.