DeCrane Aerospace Audio International
LCD-9084-301-x Installation Manual
Document # 540332, Rev A, 01/2009
Page 7 of 18
3.3.2
DO NOT
connect or disconnect the monitor while power is applied.
3.3.3
DO NOT
remove any factory-installed screws. Damage to the unit
may result and void any warranties.
3.3.4
DO NOT
expose to moisture.
3.3.5 The SP-LCD6 can be removed and stored after the monitor is set
up or it can be mounted near the monitor for frequent use. Ensure
power is removed from the monitor and/or entertainment system
before connecting or disconnecting the SP-LCD6.
3.3.6
ESD
(Electro Static Discharge) guidelines shall be followed.
3.4
Wiring Requirements
3.4.1 Clearance and Separation Requirements
The installing agency shall supply and fabricate all external cables
and mating connectors. The length and routing of external cables
should be carefully studied and planned before attempting
installation of the equipment. Allow adequate space for installation
of cable and connectors. Avoid sharp bends and placing cables
near aircraft control cables. Maintain a minimum clearance of three
(3) inches from any control cable. If wiring is run parallel to
combustible fluid or oxygen lines, maintain a separation of six (6)
inches between the lines.
3.4.2 Power Wires
DeCrane Aerospace Audio International recommends that the
chassis be electrically bonded to the airframe structure by a
conductive mounting point with <0.1 resistance using <50
impedance cable. Power and Ground wires shall be in accordance
with
M22759
or equivalent. Protect power wires with circuit
breakers or fuses located close to the electrical power source bus.