Dedicated Micros ©2007
SD Range
Enable
This shows when the alarm is enabled, and can be set for OFF,
24 hours, Schedule Day, Schedule Night and Weekend. Note that
if a Keyswitch is utilised: Keyswitch OFF uses Schedule Day and
Keyswitch ON uses Schedule Night).
Entry route
This creates deferred alarms along a specified route while
the entry time is active in compliance with BS8418, the British
Standard for remote monitoring stations. The entry/exit time
period is set on the Global Page. Diverting from the entry route
during the count down will result in the alarm being triggered
immediately. This allows staff entry without triggering an alarm,
prior to switching the system to Day mode.
Exit route
This creates deferred alarms along a specified route while the exit
time is active in compliance with BS8418, the British Standard for
remote monitoring stations. The entry/exit time period is set on the
Global Page. Diverting from the exit route during the count down
will result in the alarm being triggered immediately. This allows
staff to leave without triggering an alarm.
Activate relay mode
The alarm can be used to trigger one of the four available relays.
The alarm will trigger the selected relay until the alarm ends.
Remote alarm reporting
Enable this to send a report to an RVRC on receipt of an alarm.
Ensure that the Report Settings have been configured in the
Alarms -> Remote Reporting menu
Email on Alarm
Enable this to send an email on receipt of an alarm. Ensure
that the email settings have been configured in Network->Email
settings.
Log event
The SD DVR can record all Events, both Alarms and Activity.
Enable this to have the event written to the log.
Switch to camera
The SD DVR can display the primary camera associated with this
alarm on the operator monitor.
Sounder
The unit has a buzzer which can sound for five seconds when an
alarm or activity are detected.
Global (Red)
This button will open the Global Alarms settings (see Global
Alarms below).
Remote Reporting (Yellow)
This button will open the Remote Reporting settings (see Remote
Alarm Reporting below).
Cancel (Purple)
Settings are automatically saved when the page is closed. Use
this button to cancel any changes before navigating away from
the page.
Save (Grey)
To ‘manually’ save changes whilst in a menu page, select the
Save button.