3 Technical specifications
3.1
Homologations
3.1.1
Directives
This product complies with the requirements of the following European
Directives and Standards:
Pressure Equipment Directive 2014/68/EU
Low Voltage Directive 2014/35/EU
Generic standard: EN 60335-1
Relevant standard: EN 60335-2-40
Electromagnetic Compatibility Directive 2014/30/EU
Generic standards: EN 61000-6-3, EN 61000-6-1
Relevant Standard: EN 55014
This product conforms to the requirements of European Directive
2009/125/EC on the ecodesign of energy-related products.
In addition to the legal requirements and guidelines, the supplementary
guidelines in this manual must also be followed.
Supplements or subsequent regulations and guidelines that are valid at
the time of installation shall apply to all regulations and guidelines
specified in this manual.
3.2
Technical data
3.2.1
Heat pump
Maximum operating pressure: 0.3 MPa (3 bar)
Tab.3
Conditions of use
AWHP 4.5 MR
AWHP 6 MR-3
AWHP 8 MR-2
AWHP 11 MR-2
AWHP 11 TR-2
AWHP 16 MR-2
AWHP 16 TR-2
Limit water op
erating temper
atures in heat
ing mode
+18 °C/+55 °C
+18 °C/+60 °C
+18 °C/+60 °C
+18 °C/+60 °C
+18 °C/+60 °C
Outdoor air op
erating temper
ature limits in
heating mode
-15° C/+35 °C
-15° C/+35 °C
-20° C/+35 °C
-20° C/+35 °C
-20° C/+35 °C
Water operat
ing temperature
limits in cooling
mode
+7°C / +25°C
+7°C / +25°C
+7°C / +25°C
+7°C / +25°C
+7°C / +25°C
Outdoor air op
erating temper
ature limits in
cooling mode
+7 °C/ +46 °C
+7 °C/ +46 °C
+7 °C/ +46 °C
+7 °C/ +46 °C
+7 °C/ +46 °C
Tab.4
Heating mode: outside air tempe7 °C, water temperature at the 35 °C. Performances in accordance
with EN 14511-2.
Measure
ment type
Unit
AWHP 4.5
MR
AWHP 6
MR-3
AWHP 8
MR-2
AWHP 11
MR-2
AWHP 11
TR-2
AWHP 16
MR-2
AWHP 16
TR-2
Heat output kW
4.6
5.82
7.9
11.39
11.39
14.65
14.65
Coefficient
of Perform
ance (COP)
5.11
4.22
4.34
4.65
4.65
4.22
4.22
3 Technical specifications
16
200 ESL HYBRID
7613346 - v05 - 13112018