3.2.3
Weight
Tab.11 Indoor module
Indoor module
Unit
200 ESL HYBRID 4–8
200 ESL HYBRID 11–16
Weight empty
kg
129
131
Total weight with water
kg
324
326
Refer to the boiler manual to calculate the total weight of the indoor
module combined with the boiler.
Tab.12 Outdoor unit
Outdoor
unit
Unit
AWHP 4.5
MR
AWHP 6
MR-3
AWHP 8
MR-2
AWHP 11
MR-2
AWHP 11
TR-2
AWHP 16
MR-2
AWHP 16
TR-2
Weight
empty
kg
54
42
75
118
130
118
130
3.2.4
Combination heaters with medium-temperature heat
pump
Tab.13 Technical parameters for heat pump combination heaters (parameters declared for medium-temperature application)
Product name
200 ESL Hybrid
4.5MR
+ EFU C 19
200 ESL Hybrid
6MR-3
+ EFU C 24
Air-to-water heat pump
Yes
Yes
Water-to-water heat pump
No
No
Brine-to-water heat pump
No
No
Low-temperature heat pump
No
No
Equipped with a supplementary heater
Yes
Yes
Heat pump combination heater
Yes
Yes
Rated heat output under average conditions
(1)
Prated
kW
8
8
Rated heat output under colder conditions
(1)(1)
Prated
kW
6
6
Rated heat output under warmer conditions
(1)(1)
Prated
kW
4
5
Declared capacity for heating for part load at an indoor
temperature of 20 °C and outdoor temperature
T
j
T
j
= -7°C
Pdh
kW
3.8
3.5
T
j
= +2 °C
Pdh
kW
4.3
4.5
T
j
= +7 °C
Pdh
kW
4.5
4.8
T
j
= +12 °C
Pdh
kW
5.5
5.2
T
j
= bivalent temperature
Pdh
kW
4.3
4.5
T
j
= operation limit temperature
Pdh
kW
3.9
3.6
Bivalent temperature
T
biv
°C
2
2
Degradation co-efficient
(2)
Cdh
—
1.0
1.0
Seasonal space heating energy efficiency under average
conditions
ƞ
s
%
135
132
Seasonal space heating energy efficiency under colder
conditions
ƞ
s
%
122
121
Seasonal space heating energy efficiency under warmer
conditions
ƞ
s
%
172
166
Declared coefficient of performance or primary energy ra
tio for part load at an indoor temperature of 20 °C and
outdoor temperature
T
j
3 Technical specifications
7613346 - v05 - 13112018
200 ESL HYBRID
19