Product name
200 ESL Hybrid
4.5MR
+ EFU C 19
200 ESL Hybrid
6MR-3
+ EFU C 24
T
j
= -7°C
COPd
-
or
%
1.64
1.86
T
j
= +2 °C
COPd
-
or
%
3.46
3.40
T
j
= +7 °C
COPd
-
or
%
4.96
4.52
T
j
= +12 °C
COPd
-
or
%
7.35
6.70
T
j
= bivalent temperature
COPd
-
or
%
3.46
3.40
T
j
= operation limit temperature
COPd
-
or
%
1.84
1.52
Operation limit temperature for air-to-water heat pumps
TOL
°C
-10
-10
Heating water operating limit temperature
WTOL
°C
80
80
Electrical power consumption
Off mode
P
OFF
kW
0.009
0.009
Thermostat-off mode
P
TO
kW
0.049
0.049
Stand-by
P
SB
kW
0.013
0.019
Crankcase heater mode
P
CK
kW
0.055
0.055
Supplementary heater
Rated heat output
(1)(1)
Psup
kW
4.0
4.8
Type of energy input
Oil
Oil
Other specifications
Capacity control
Variable
Variable
Sound power level, indoors - outdoors
L
WA
dB
49 – 61
48 – 64
Annual energy consumption under average conditions
Q
HE
kWh
GJ
4045
6
4312
8
Annual energy consumption under colder conditions
Q
HE
kWh
GJ
4564
4
4236
3
Annual energy consumption under warmer conditions
Q
HE
kWh
GJ
1299
0
1544
0
Rated air flow rate, outdoors for air-to-water heat
pumps
—
m
3
/h
2100
2100
Declared load profile
L
L
Daily electricity consumption
Q
elec
kWh
4.020
4.816
Annual electricity consumption
AEC
kWh
845
968
Water heating energy efficiency
ƞ
wh
%
106.00
106.00
Daily fuel consumption
Q
fuel
kWh
0.000
0.000
Annual fuel consumption
AFC
GJ
0
0
(1) The rated heat output
Prated is equal to the design load for heating Pdesignh, and the rated heat output of a supplementary heater
Psup is equal to the supplementary capacity for heating sup(Tj).
(2) If
Cdh is not determined by measurement then the default degradation coefficient is Cdh = 0.9.
3 Technical specifications
20
200 ESL HYBRID
7613346 - v05 - 13112018