6 Settings
6.1
List of parameters
6.1.1
User Menu
Fig.36
1
2
MW-2000435-1
3
2
1 Sub-menu available
2 Name of the PCB or circuit
3 Setting parameters
Tab.16 List of User sub-menus
Sub-menu
Description
Name of the PCB or cir
cuit
Main heating circuit
Additional heating circuit B
Domestic hot water circuit
Central unit PCB EHC-02
Central unit PCB CU-OH01
Additional PCB for circuit B
HMI control panel
See
Boiler user guide for parameters and user instructions.
Important
CP : Circuits Parameters= Heating circuit parameters
Tab.17 List of parameters in the
/
sub-menus of the User menu
Parameter
Description
Factory setting
Factory setting
Post-operation time of the circuit pump
Can be set from 0 to 20 minutes
4 minutes
4 minutes
Room temperature set point in reduced mode
Can be set from 5 to 30°C
16°C
16°C
Room temperature set point in comfort mode
Can be set from 5 to 30°C
20°C
20°C
Do not modify this setting.
6°C
6°C
Do not modify this setting.
21°C
21°C
Do not modify this setting.
22°C
22°C
Do not modify this setting.
20°C
20°C
Set point cooling activity zone 1
Can be set from 20 to 30°C
Do not modify this setting.
30°C
30°C
Set point cooling activity zone 2
Can be set from 20 to 30°C
Do not modify this setting.
25°C
25°C
Do not modify this setting.
25°C
25°C
6 Settings
7613346 - v05 - 13112018
200 ESL HYBRID
33