Tab.39 Weighting of medium temperature heat pumps
Prated / ( Psup)
(1)(2)
II, package without hot water storage tank
II, package with hot water storage tank
0
1.00
1.00
0.1
0.70
0.63
0.2
0.45
0.30
0.3
0.25
0.15
0.4
0.15
0.06
0.5
0.05
0.02
0.6
0.02
0
≥ 0.7
0
0
(1) The intermediate values are calculated by linear interpolation between the two adjacent values.
(2) Prated is related to the preferential space heater or combination heater.
Tab.40 Package efficiency (temperature reg heat pump)
200 ESL Hybrid 4MR
+ EFU C 19
200 ESL Hybrid 4.5MR
+ EFU C 19
200 ESL Hybrid 6MR-2
/ 200 ESL Hybrid 6MR-3
+ EFU C 24
IniControl 2
%
136
137
134
Tab.41 Package efficiency (temperature reg heat pump)
200 ESL Hybrid 8MR-2
+ EFU C 24
200 ESL Hybrid 11MR-2
+ EFU C 19
200 ESL Hybrid 16MR-2
+ EFU C 24
IniControl 2
%
136
134
131
12 Appendix
7613346 - v05 - 13112018
200 ESL HYBRID
61