3 Technical specifications
3.1
Homologations
3.1.1
Certifications
This product complies with the requirements of European directives and
the following standards:
Low Voltage Directive 2006/95/EC.
Relevant Standard: EN 60.335.1.
Relevant standard: EN 60.335.2.21.
Electromagnetic Compatibility Directive 2004/108/EC
Relevant standards: EN 50.081.1, EN 50.082.1, EN 55.014
3.1.2
Factory test
Before leaving the factory, each appliance is tested for the following:
Water tightness
Air tightness
Electrical tests (components, safety).
3.1.3
Directive 97/23/CE
This product conforms to the requirements of European Directive
97/23/EC, article 3, paragraph 3, on pressure equipment.
3.2
Technical data
3.2.1
Specifications of the DHW tank
Tab.1
Unit
DHW tank 220 SHL
Primary circuit (heating
water)
Maximum operating
temperature
°C
95
Maximum operating
pressure
bar (MPa)
3 (0.3)
Primary circuit (Solar
circuit fluid)
Maximum operating
temperature
°C
135
Maximum operating
pressure
bar (MPa)
6 (0.6)
Exchanger capacity
l
8.4
Exchange surface
m
2
1.25
Secondary circuit (do
mestic water)
Maximum operating
temperature
°C
95
Maximum operating
pressure
bar (MPa)
10 (1.0)
Water capacity
l
220
3 Technical specifications
8
220 SHL
300028214 - v06 - 02022017