Product name
MIV-4
AWHP 4 MR
MIV-4
AWHP 6 MR-2
MIV-4
AWHP 8 MR-2
Supplementary heater
Rated heat output
(24)
Psup
kW
0.0
0.0
0.0
Type of energy input
Electricity
Electricity
Electricity
Other characteristics
Capacity control
Variable
Variable
Variable
Sound power level, indoors - outdoors
L
WA
dB
53 – 64
53 – 65
53 – 65
Annual energy consumption under average con
ditions
Q
HE
kWh
1489
2124
3316
Annual energy consumption under colder condi
tions
Q
HE
kWh
2757
3721
4621
Annual energy consumption under warmer condi
tions
Q
HE
kWh
887
1492
1904
Rated air flow rate, outdoors for air-to-water heat
pumps
—
m
3
/h
2100
2100
3300
Declared load profile
L
L
L
Daily electricity consumption
Q
elec
kWh
4.816
4.816
4.816
Annual electricity consumption
AEC
kWh
968
968
968
Water heating energy efficiency
ƞ
wh
%
106.00
106.00
106.00
Daily fuel consumption
Q
fuel
kWh
0.000
0.000
0.000
Annual fuel consumption
AFC
GJ
0
0
0
(1) The rated heat output
Prated is equal to the design load for heating Pdesignh, and the rated heat output of a supplementary heater Psup is
equal to the supplementary capacity for heating
sup(Tj).
(2) If
Cdh is not determined by measurement, the default degradation coefficient is Cdh = 0.9.
Tab.14 Technical parameters for heat pump combination heaters (parameters declared for medium-temperature application)
Product name
MIV-4
AWHP 11 MR-2
MIV-4
AWHP 16 MR-2
Air-to-water heat pump
Yes
Yes
Water-to-water heat pump
No
No
Brine-to-water heat pump
No
No
Low-temperature heat pump
No
No
Equipped with a supplementary heater
Yes
Yes
Heat pump combination heater
Yes
Yes
Rated heat output under average conditions
(1)
Prated
kW
6
8
Rated heat output under colder conditions
(13)
Prated
kW
4
7
Rated heat output under warmer conditions
(13)
Prated
kW
8
13
Declared capacity for heating for part load at indoor
temperature 20 °C and outdoor temperature
T
j
T
j
= -7 °C
Pdh
kW
6.8
9.0
T
j
= +2 °C
Pdh
kW
8.2
11.9
T
j
= +7 °C
Pdh
kW
9.0
12.9
T
j
= +12 °C
Pdh
kW
10.1
15.4
T
j
= bivalent temperature
Pdh
kW
6.2
8.3
T
j
= operation limit temperature
Pdh
kW
6.2
8.3
Bivalent temperature
T
biv
°C
-10
-10
Degradation coefficient
(2)
Cdh
—
1.0
1.0
3 Technical specifications
20
MIV-4