46
2 / INSTALLING YOUR APPLIANCE
EN
Warning
This appliance is delivered with a H 05
VVF power cord that has three-0.75 mm2
conductors (neutral, phase and ground). It
must be connected to the main power supply
(which should be a 220-240 V single phase
current) via a CEI 60083 standardised socket
that should remain accessible after installa-
tion, in keeping with installation guidelines.
We cannot be held responsible for any acci-
dent resulting from an inexistent, defective
or incorrect ground lead. The fuse for your
installation must be 10 or 16A. If the power
cable is damaged, call the after-sales serv-
ice department in order to avoid danger.
Warning
If the electrical installation at your resi-
dence requires any changes in order to hook
up your appliance, call upon a professional
electrician.
Warning
If the hood displays any malfunctions,
unplug the appliance or remove the fuse cor-
responding to the electrical socket where
your appliance is plugged in.
•
ELECTRICAL CONNECTIONS
During installation and maintenance opera-
tions, the appliance must be unplugged from
the electrical grid; fuses must be cut off or re-
moved.
Carry out the electrical connection after as-
sembly and mounting are completed.
Ensure that:
- the electrical installation has sufficient volt-
age,
- the electrical wires are in good condition,
- the diameter of the wires complies with the
installation requirements.