3 Technical specifications
3.1
Homologations
3.1.1
Certifications
Electrical Conformity / CE Marking
This product complies with the requirements of the following European Di
rectives and Standards:
Low Voltage Directive 2006/95/EC.
Relevant standard: EN 60335-1
Electromagnetic Compatibility Directive 2004/108/EC
Relevant standards: EN 55014-1:2006 + A1 + A2 / EN 55014–2:2006 +
A1 + A2
3.1.2
2014/68/UE Directive
This product conforms to the requirements of European Directive
2014/68/UE, article 4, paragraph 3, on pressure equipment.
3.1.3
Factory test
Before leaving the factory, each appliance is tested for the following:
Water tightness
Air tightness
Electrical safety.
3.2
Technical data
3.2.1
Specifications of the DHW sensor
Important
Tolerance: +/- 5 Ohm
Tab.2
Temperature (in °C)
10
20
25
30
40
50
60
70
80
Resistance (in ohms)
19691
12474
10000
8080
5372
3661
2536
1794
1290
3.2.2
Appliance specifications
Tab.3
Model
Unit
TWH 200 E
TWH 300 E
TWH 300 EH
Heating time (15-51 °C)
hours
5
7
7
Capacity
litres
215
270
260
Weight (empty)
kg
92
105
123
Refrigerant fluid R134a
kg
1.45
1.45
1.45
R-134a refrigerant
(1)
tCO
2
e
2.075
2.075
2.075
Output (heat pump) with air
temperature = 15 °C
W
1700
1700
1700
Immersion heater output
W
2400
2400
2400
Operating pressure
MPa (bar)
1.0 (10)
1.0 (10)
1.0 (10)
3 Technical specifications
300026515 - v09 - 25072017
13