Tab.7
Maximum length by accessory as a function of the pressure drops
Accessories
Package
Equivalent length in
m
90° galvanised elbow (diameter 160 mm)
EH77
1.0
Adapter sleeve (diameter 160 mm)
EH205
1.5
Insulated flexible ducting (diameter 160 mm - length 3 m)
EH206
3.0
Wall duct (diameter 160 mm) + finishing plate
EH208
7.0
Aluminium outdoor grille (diameter 160 mm)
EH209
8.0
PPE pipe (diameter 160 mm, length 2x 1 m) + two sleeves
EH272
0.2
Two 90° elbows (PPE) (diameter 160 mm) + two sleeves
EH273
0.2
Black roof outlet (diameter 160 mm)
EH275
2.0
Waterproof base for 25° to 45° pitched roofs (diameter 160 mm)
EH277
2.0
Reduced elbow kit
EH434
6.0
Outdoor grille for air inlet and outlet (diameter 160 mm)
EH558
1.0
Note
Add together all of the lengths of accessories used once or more
in the installation. The total length must not exceed 26 m for a di
ameter of 160 mm.
5.4.3
Main dimensions
TWH 200 E - TWH 300 E
Fig.10
MW-1000357-2
50°
690
A
249
B
C
3
4
1025
810
4
(1)
1
2
1 Impressed current anode
2 2.4 kW steatite immersion heater
3 Domestic hot water outlet G 3/4"
4 Domestic hot water inlet G 3/4"
(1) Adjustable feet
Tab.8
TWH 200 E
TWH 300 E
A
1690
2000
5 Installation
300026515 - v09 - 25072017
23