5.8.3
Positioning the control system in the living room
1. Drill two holes 6 mm in diameter.
2. Put the plugs in place.
3. Attach the wall support.
4. Connect the two wires on the command module.
5. Position the control system module.
5.9
Electrical connections
5.9.1
Recommendations
Warning
Only qualified professionals may carry out electrical connec
tions, always with the power off.
Do not connect the power supply directly to the peak/off-peak
rate contact.
Earthing must comply with the prevailing installation standards.
Power the appliance via a circuit that includes a type D curve omnipolar 16
A circuit breaker with a contact opening distance of 3 mm or more.
The water heater is delivered with a 3G cable. If the power supply cable is
damaged, it must be replaced by the manufacturer, its after sales service
or persons with similar qualifications in order to prevent any danger.
The electricity supply is connected to the mains by connection cable (~230
V, 50 Hz) and electrical socket.
The peak/off-peak rate connection is made on the terminal block.
Fig.24
1
2
3
6
MW-1000380-1
Fig.25
4
5
MW-1000381-1