5 Installation
5.1
Installation regulations
Caution
The appliance must be installed and maintained by a certified
professional in accordance with prevailing statutory texts and
codes of practice.
5.2
Package list
5.2.1
Standard delivery
The standard delivery includes:
a thermodynamic water heater
two dielectric unions (supplied in the documentation bag for the water
heater)
two lip gaskets
a condensates discharge hose
the Installation and Service Manual
the User Guide
5.2.2
Accessories
Tab.7
Description
Package no.
90° galvanised elbow (diameter 160 mm)
EH77
Adapter sleeve (diameter 160 mm)
EH205
Insulated flexible ducting (diameter 160 mm - length 3 m)
EH206
Set of two attachment clamps (diameter 160 mm)
EH207
Wall duct (diameter 160 mm) + finishing plate
EH208
Aluminium outdoor grille (diameter 160 mm)
EH209
PPE pipe (diameter 160 mm, length 2x 1 m) + two sleeves
EH272
Two 90° elbows (PPE) (diameter 160 mm) + two sleeves
EH273
Two PPE sleeves (diameter 160 mm)
EH274
Black roof outlet (diameter 160 mm)
EH275
Waterproof base for flat roofs (diameter 160 mm)
EH276
Waterproof base for 25° to 45° pitched roofs (diameter 160 mm)
EH277
Reduced elbow kit
EH434
Connection kit for safety unit
ER208
Outdoor grille for air inlet and outlet (diameter 160 mm)
EH558
5.3
Storage and transport of the appliance
Caution
Have two people available.
Use a 3-wheel hand truck.
Handle the appliance with gloves.
The appliance cover cannot be used for transport operations.
The cover is not capable of withstanding heavy weights.
300 model: allow a minimum room height of around 2.15 m
200 model: allow a minimum room height of around 1.84 m.
The thermodynamic water heater must be stored and transported in its
packaging and not filled with water.
Permissible ambient transport and storage temperatures: -20 to +60 °C.
5 Installation
18
300026515 - v10 - 28082018