Tab.8
TWH 200 E
TWH 300 E
TWH 300 EH
A (mm)
1690
2000
2000
To ensure adequate access and facilitate maintenance, allow sufficient
space around the appliance.
200 model: Allow a minimum distance of 0.4 m on both sides of the
appliance and a minimum room height of around 1.84 m for operation
without air ducts.
300 model: Allow a minimum distance of 0.4 m on both sides of the
appliance and a minimum room height of around 2.15 m for operation
without air ducts.
Pipe length
Caution
Do not use accessories that may cause considerable pressure
drops (extraction grid with mosquito screen, partially extended
flexible duct, etc.). If the pressure drops are greater, the
performance of the appliance will be impaired and the charging
times increased.
Tab.9
Maximum length of the air connection
m
Diameter 160 mm
26
Tab.10 Maximum length by accessory as a function of the pressure drops
Accessories
Package
Equivalent length in
m
90° galvanised elbow (diameter 160 mm)
EH77
1.0
Adapter sleeve (diameter 160 mm)
EH205
1.5
Insulated flexible ducting (diameter 160 mm - length 3 m)
EH206
3.0
Wall duct (diameter 160 mm) + finishing plate
EH208
7.0
Aluminium outdoor grille (diameter 160 mm)
EH209
8.0
PPE pipe (diameter 160 mm, length 2x 1 m) + two sleeves
EH272
0.2
Two 90° elbows (PPE) (diameter 160 mm) + two sleeves
EH273
0.2
Black roof outlet (diameter 160 mm)
EH275
2.0
Waterproof base for 25° to 45° pitched roofs (diameter 160 mm)
EH277
2.0
Reduced elbow kit
EH434
6.0
Outdoor grille for air inlet and outlet (diameter 160 mm)
EH558
1.0
Important
Add together all of the lengths of accessories used once or more
in the installation. The total length must not exceed 26 m for a
diameter of 160 mm.