Condensate discharge
1. Fit a siphon into the condensate discharge duct.
Caution
If no siphon is fitted, there is a risk of problems with the
condensate discharge when the compressor is running: air may
be drawn in by the condensate discharge.
2. Attach the run-off collector.
5.8
Electrical connections
5.8.1
Recommendations
Warning
Only qualified professionals may carry out electrical
connections, always with the power off.
Do not connect the power supply directly to the peak/off-peak
rate contact.
Earthing must comply with the prevailing installation standards.
Power the appliance via a circuit that includes a type-D curve omnipolar
16 A circuit breaker with a contact opening distance of 3 mm or more.
The water heater is delivered with a 3G cable. If the power supply cable is
damaged, it must be replaced by the manufacturer, its after sales service
or persons with similar qualifications in order to prevent any danger.
The electricity supply is connected to the mains by connection cable (~230
V, 50 Hz) and electrical socket.
The peak/off-peak rate connection is made on the terminal block.
The control panel for the appliance must remain switched on to ensure
that the impressed current anode can operate. Failure to comply with this
instruction may cause deterioration to the water heater tank and cancel its
warranty.