Tab.15 Electrical connection
Maximum cable length for dedicated Smart TC° bus
50 m
Maximum cable resistance
2 x 5 ohm
Tab.16 Wi-Fi connection
Supported frequency band
2.4 Ghz (802.11b/g)
Tab.17 Ambient conditions
Storage temperature
from - 25 °C to 70 °C
Relative humidity
from 5 % to 95 %
Condensation is not allowed
Operating conditions
from 0 °C to 60 °C
Tab.18 Temperature
Room temperature measurement range
from 0 °C to 50 °C
Temperature control area
(1) Depends on appliance.
Tab.19 Compliant with standards
EMC: 108/2004/EC, EN 55022, 55014
Immunity: EN2-6-61000
EN2-6-61000 (EMC part 6.2 Generic Standards)
ETSI-EN 17-489 301 (Electromagnetic compatibility and radio spectrum matters)
R&TTE Directive 5/1999/EC
EN 1-60950 (ITE – Safety – Part 1: General Requirements)
Low voltage directive (95/2006/EC)
WEEE directive (96/2002/EC) (disposal requirements)
Drop test: IEC 32-2-60068
Protection classification: IP21
8.4
ErP information
8.4.1
Product fiche
Tab.20 Product fiche
De Dietrich - Smart TC°
Smart TC°
Smart TC°
Class
IV
V
VI
Contribution to space heating energy efficiency
%
2
3
4
(1) Combined with On/Off appliance
(2) Combined with modulating appliance
(3) Combined with modulating appliance and outdoor sensor
8 Appendix
7720691 - v.01 - 05102018
43