4.4.5
Setting the threshold for auto mode
You can set the threshold temperature for switching between heating
and/or cooling.
1. Enter the main menu.
2. Select Settings.
3. Select RedRoomTempCool Zone.
4. Use the rotary dial to change the threshold setpoint.
4.5
Installer settings
When you enter the Installer menu, the display shows a warning that the
settings in the Installer Menu may affect the performance of your
appliance. It may be a better idea that your installer does these settings.
4.5.1
Changing the heating curve
The heating curve relates the water temperature of the heating system to
the outside temperature. With a good heating curve the installation can
maintain a constant temperature in the room.
1. Enter the main menu.
2. Select Installer.
3. Confirm the selection.
4. Select Yes to continue.
5. Confirm the selection.
6. Select Heating Curve.
Important
The display shows Heating Curve only if your installation is fit for
this option.
7. Confirm the selection.
The display shows the heating curve diagram.
8. Short-press the select button to select the central curve point.
9. Use the rotary dial to move the central curve point over the oblique
line in order to see the outside temperatures and the related water
temperatures in the bottom-left corner.
10. Short-press the select button to deselect the central curve point.
11. Use the rotary dial to select Min: (the minimum water temperature of
the appliance).
12. Confirm the selection.
13. Use the rotary dial to change the temperature.
14. Confirm the change.
15. Use the rotary dial to select Slope: (the steepness of the heating
curve).
16. Confirm the selection.
Fig.43
AD-3001006-01
....... .......
....... ....... ....... ....... ....... ....... ....... ....... ....... .......
..
.
|
..
.
}
<1
Fig.44
AD-3001253-01
....
..... :
....
..... :
....... : .. ..
....... : .. ..
.......
<1
4 Customisation
30
7720691 - v.01 - 05102018