Parameter Description
Adjustment range
Factory
setting
EGC 25
p1
Flow temperature: T
SET
20 to 90 °C
80
p2
Domestic hot water
temperature: T
SET
40 to 65 °C
55
p3
Heating / DHW mode
0 = Heating deactivated / DHW deactivated
1 = Heating activated / DHW activated
2 = Heating activated / DHW deactivated
3 = Heating deactivated / DHW activated
1
p4
ECO mode
0 = Comfort
1 = Energy-saving mode
2 = Management using a programmable thermostat
2
p5
Anticipation resistance
0 = No anticipation resistance for the ON/OFF thermostat
1 = Anticipation resistance for the ON/OFF thermostat
0
p6
Display screen
0 = Simple
1 = Comprehensive
2 = Automatic switching to simple after 3 minutes
3 = Automatic switching to simple after 3 minutes; Key blocking is
active
2
p7
Post-circulation of the pump 1 to 98 minutes
99 minutes = continuous
2
p8
Brightness of display
lighting
0 = Low
1 = High
1
5.3.2.
Modification of the user-level parameters
Parameters
p1
to
p8
can be modified by the user in order to meet
central heating and DHW comfort needs.
5. Operating the appliance
EGC 25
19
09/02/2016 - 300026082-001-05