background image

User Manual

UserManual

Digital Weighing Indicator

Digital Weighing Indicator

DIGITAL WEIGHING INDICATOR

- 7 -

DIGITAL WEIGHING INDICATOR

- 6 -

Connecting Load Cell to Indicator

Power On and Zero Auto

Manual Zero

Tare

1. 

The 5-pin (2.54MM) socket is used to connect to the load cell, as indicated in the graph below. 

 

Please Note: Pin 1 EX+; Pin 2 EX-; Pin 3 SHIELD; Pin 4 IN+; Pin 5: In-  

2. 

When the 4-pin shielded cable is connected, the indicator has a long distance function.  

3. 

The indicator must be connected to the load cell and the shield cable of the load cell 

 

Must be grounded. 

4. 

The sensor and indicator are static sensitive devices. Do not operate under high voltage. 

Operation

1. 

The indicator will perform “999999-000000” to self-check when turning on. Then it will enter 

 

weighing mode. 

2. 

When powered on, if loading weight on the scale deviates from the zero point, but still within auto 

 

zero setting range, the indicator will set to zero automatically; if it is out of auto zero setting 

 

range, it is necessary to adjust the zero point or recalibrate or reset.

1. 

In weighing mode, when there is a degree of tolerance after removing weight, press [ZERO] to set 

 

the indicator to zero. 

2. 

If the displayed value deviates from the zero point, but it is still within the manual zero-range, the 

 

[ZERO] key will return the indictor to zero. If not within the manual zero-range, then the [ZERO] 

 

key will not function. *If this is the case, please recalibrate or reset zero parameters. 

3. 

Only when a stable indication is displayed can the zero operation function. 

1. 

When the indicator is in weighing mode, and the displaying positive weight is stable, pressing the 

 

[Tare] key will deduct the displayed weight value as tare weight. The indicator  will then display 

 

net weight as “0” and the Tare indicator is on. 

Accumulation

1. 

In weighing mode, when the displayed value is positive and stable, press the [*] key to accumulate 

 

the present weight and display the accumulated weight. The accumulate indicator “(*)” will be 

 

on. Press this key again and it will go back to weighing mode and the accumulate indication “(*)” 

 

will not be displayed. The next accumulation operation must be performed after the weight 

 

is returned to zero. When the accumulated weight is displayed, press the [Func] key to clean 

 

the accumulated weight in Memory and press [*] to return to weighing mode. If the accumulated 

 

weight needs to be checked, please keep the load of the platform at zero, then press [*] to display 

 

the accumulated weight. 

Connect to Load Cell

CPU

A/D

CONVERSION

CN1

CN3

CN4

CN2

EX+

EX-

SHELD

IN+

IN-

Summary of Contents for D1047067

Page 1: ...Digital Weighing Indicator User Manual WWW DEELAT COM ...

Page 2: ...Indication 13 Chargeable Battery 13 Maintenance 14 Notes 15 Model Deelat Floor Scale weighing indicator Accuracy GradeIII n 3000 Sample Rate 10 times second A D conversion Δ Load cell sensitivity 1 5 3mV V Scale interval 1 2 5 10 20 50 for selection Display 6 bits LCD 6 state indicating signals Scoreboard interface optional In serial output mode current loop signal transmission distance 50m Commun...

Page 3: ... come into counting mode Press this button to accumulating the weight in weighing mode Press this button for sample taking in counting mode Press this button to tare in weighing mode Press this button to zero in weighing mode Press this button to turn on off the scale Press this button to stay in weighing mode or Press this button to save move in set mode FUNC TARE ZERO Unit Kg Charge A12 COUNT FU...

Page 4: ... zero 2 If the displayed value deviates from the zero point but it is still within the manual zero range the ZERO key will return the indictor to zero If not within the manual zero range then the ZERO key will not function If this is the case please recalibrate or reset zero parameters 3 Only when a stable indication is displayed can the zero operation function 1 When the indicator is in weighing ...

Page 5: ... keep the result from the last sampling 1 In weighing mode hold and press Func for 5 seconds and it will enter user function setting mode mode P There are 12 modes from P1 to P12 Press to choose the mode and press Tare to choose the parameter The description of parameters is as follows P1 kg Lb change X 1 kg display X 2 Lb display P2 automatically power off X 1 N A X 2 Power off in 10 minutes X 3 ...

Page 6: ...e following the 1st is starting the bit the 10th is the stop bit and the middle are 8 data bits Communication mode as follows 1 In continuous mode The data transmitted is weight Gross weight or net weight The format of G W ww000 000kg or ww000 000lb The format of N W wn000 000kg or wn000 000lb Note The position of above decimal is decided by the decimal set on the indicator 2 In command mode The i...

Page 7: ...point full range and enter into the zero point calibration mode Press ZERO when the stable signal is on and it will display End and keep the original full range point calibration Press the calibration switch under the lead sealing board at the back of the indicator and it will save the setting and return to the weighing status 4 Fast calibration for full range point Fast calibration for full range...

Page 8: ...pt anti static measures 4 Do not clean the case of indicator with intensive solvents for example benzene and nitro oils 5 Liquid and conductive substances should not come into contact with the indicator otherwise the electronic components can be damaged and the user could get shocked 6 Make sure to cut off the power supply to the indicator and relevant devices before connecting and disconnecting a...